期刊文献+

某电厂项目地下水污染物运移模拟 被引量:11

Simulation on Groundwater Pollutant Migration of a Power Plant Project
在线阅读 下载PDF
导出
摘要 文章运用Visual MODFLOW模拟预测以下两种情况下石油类污染物泄漏后,地下水中污染物运移情况。(1)防渗破损,无监控及应急施情况下,地下水中污染物运移情况;(2)防渗破损,但有监控及应急措施情况下,地下水中污染物运移情况。预测结果表明,两种情况对下水均会造成影响。但是第二种情况对地下水的影响范围是可控的,并提出地下水污染监控与应急措施。 The paper predict that the leakage of petroleum pollutants transport in groundwater conditions based on Visual MODFLOW, in the following two cases. The contaminant transport in groundwater without seepage damaging, having monitoring and emergency measures. The contaminant transport in groundwater under seepage damaging, but having control measures. Forecast results indicate that contaminant will affect the groundwater in both cases. But under the second case, the impact on groundwater is controllable, and propose groundwater poUution monitoring and emergency measures.
出处 《广东化工》 CAS 2014年第4期66-67,56,共3页 Guangdong Chemical Industry
关键词 污染物运移 监控及应急措施 visual MODFLOW contaminant transport monitoring and emergency measures