摘要
分析了新钢公司第一动力厂12万m3转炉煤气柜柜内煤气发生泄漏的原因,得出结论为钢丝绳断裂所致,采取措施处理后,使气柜得以安全稳定运行。
The causes of gas leakage in the 120000 m3 gas holder of Xinyu Steel were analyzed and it was concluded that a wire rope fracture caused the leakage. After counter-measures were taken to treat the leakage the gas holder has operated safely and stably.
出处
《冶金动力》
2014年第2期22-23,共2页
Metallurgical Power
关键词
气柜
煤气
泄漏
原因
处理
gas holder
gas
leakage
cause
treatment