期刊文献+

复叠式空气源热泵系统的控制稳定性研究 被引量:5

Research on Control Stability of Cascade Air-source Heat Pump
在线阅读 下载PDF
导出
摘要 针对可在不同环境温度下制取高温热水的复叠式空气源热泵系统,运用二级压缩比大致相等的原则确定最优中间温度从而控制中间冷凝压力的方法。采用适用性较好的比例-积分-微分(Proportion Integration Differentiation,PID)算法,利用可编程逻辑控制器(Programmable Logic Controller,PLC)进行核心控制,通过实验验证了在不同的室外环境温度条件下,面对负荷的变化,该系统控制快速、平稳且精确,实现了对复叠式空气源热泵系统的优化控制。 For the cascade air-source heat pump operated under different environment temperature, the proper control of intermediate pressure is important. In this paper the principle that two stage compression ratio is approximately equal is used to determine the interme-diate pressure at the optimal middle temperature. The proposed method and control strategy were implemented by highly applicable Propor tion Integration Differentiation (PID) algorithm and Programmable Logic Controller(PLC). A test was conducted, and it showed that the control method was sensitive, stable and accurate with various outside conditions and indoor loads.
出处 《制冷学报》 CAS CSCD 北大核心 2014年第1期38-45,共8页 Journal of Refrigeration
基金 国家自然科学基金(51208298)资助项目 上海市研究生创新基金项目(JWCXSL1202) 上海市教委科研创新项目(13YZ070) 上海市教委重点学科建设项目(J50502) 上海高校青年教师培养资助计划(ZZslg12020)资助~~
关键词 空气源热泵 复叠式 PID PLC 控制 稳定性 air-source heat pump cascade PID PLC control stability
  • 相关文献

参考文献7

二级参考文献3

  • 1SIEMENS(China) AG.SIMATIC S7-200 Applications [Z]. 2002: 83-85.
  • 2汪国凡.最新供热空调设计实用手册[M]吉林电子出版社,2005.
  • 3朱瑞琪,陈文勇,吴业正.电子膨胀阀的控制[J].流体机械,1998,26(5):20-25. 被引量:25

共引文献9

同被引文献64

引证文献5

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部