摘要
以大型商业综合体为例,对大型商场内建筑中部的疏散楼梯难以直接通向室外这一问题进行分析,提出将通向外廊和室外平台的出口计入安全出口,并对其可行性、设计方案及采用该设计方案时应注意的问题进行了探讨。结果表明,当外廊和室外平台满足一定的条件时,可将其计入安全出口。
The water system in some super high -rise building and its structure has been analyzed in this article as an example, its details of the water - supply system have been analyzed and its water - system pressure distribution and yield have been verified. Then, these data has been compared with the related articles in Code for fire protection design of high- rise buildings to see if it meets the requirements of the rule. The article provides some reference to the water system design of super high - rise buildings.
出处
《武警学院学报》
2013年第12期47-49,共3页
Journal of the Armed Police Academy
关键词
室内步行街
外廊
室外平台
安全出口
super high -rise building
water -supply system
zoned water supply