摘要 用 OBSCAN-Ⅱ眼前节诊断系统对50例(100眼)正常成人角膜进行全角膜厚度检测,重点观测角膜最薄点的厚度位置。结果表明,角膜最薄点厚度的平均值为(554.33±34.46)μm,与角膜中心点厚度相关系数为0.976,但最大相差值可达23μm,角膜最薄点位置在角膜中心点(0.58±0.26)mm半径范围内,以颞下方为多。结果提示:OB-SCAN-Ⅱ眼前节诊断系统对角膜最薄点的检测更为精确。 The thickness of all cornea in 100 eyes of 50 normal adults was measured by using OBSCAN-Ⅱ anterior segment system to emphatically observe the value and site of the thinnest cornea. The results showed the mean value at the point of the thinnest thickness was (554. 33±34. 46)μm, significantly correlated with corneal center (r= 0.976). The largest deviation was 23μm. The site of the thinnest cornea was located at (0. 58±0. 26) mm radius of corneal central point most spreading on inferotemporal. The results suggested that OBSCAN-Ⅱ anterior segment system can more accurately measure the thinnest corneal point.
作者 刘磊
出处 《同济医科大学学报》 CSCD 2000年第6期592-593,共2页 Acta Universitatis Medicinae Tongji
  • 相关文献

参考文献3

  • 1张淑芳 邓惠娟 等.我国人正常眼的角膜厚度[J].中华眼科杂志,1981,17(4):226-226.
  • 2李凤鸣,眼科全书,1996年,124页
  • 3张淑芳,中华眼科杂志,1981年,17卷,4期,226页

共引文献14

同被引文献9

  • 1李绍伟,李赵霞,史伟云,曾庆延,晋秀明.233例圆锥角膜的临床特点分析[J].中华眼科杂志,2005,41(7):610-613. 被引量:22
  • 2郭玉峰,赵少贞.Pentacam眼前节测量及分析系统的临床应用进展[J].国际眼科纵览,2006,30(1):10-14. 被引量:38
  • 3黎晓新.眼的解剖和生理//葛坚,赵家良,崔浩.眼科学.北京:人民卫生出版社,2005:55-97.
  • 4朱秀安.眼的解剖组织学//李凤鸣.中华眼科学.北京:人民卫生出版社.2004:89.
  • 5Ashwin PT, Shah S, Pushpoth S, et al. The relationship of central corneal thickness (CCT) to thinnest central cornea (TCC) in healthy adults. Cont Lens Anterior Eye,2009,32:64- 67.
  • 6Demirbas NH, Pflugfelder SC. Topographic pattern and apexlocation of keratoconus on elevation topography maps. Cornea, 1998,17:476-484.
  • 7Klein SR, Epstein R J, Randleman JB, et al. Corneal ectasia after laser in situ keratomileusis in patients without apparent preoperative risk factors. Cornea,2006,25:388-403.
  • 8A1Mahmoud T, Priest D, Munger R, et al. Correlation between refractive error, corneal power, and thickness in a large population with a wide range of ametropia. Invest Ophthalmol Vis Sci,2011,52 : 1235-1242.
  • 9王霁雪,吴荒,杨隆艳,郑雅娟.Orbscan—II、Pentacam及超声测厚仪角膜厚度测量值的比较[J].中华眼视光学与视觉科学杂志,2010,12(1):64-67. 被引量:19

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部