摘要
游泳馆建筑温湿度要求与其他公共建筑不同,能耗较大,在舒适度和节能之间选择一个合适的点,并据此合理地确定其空调方式,对游泳馆建筑节能至关重要。目前国内关于游泳馆等方面的设计规范、标准尚不完善,成功的案例不多,通过总结南京市某游泳馆投入使用后1年的监测数据,从实践的角度探讨游泳馆建筑空调节能设计思路。
The building temperature and humidity requirements of natatorium are different from other public buildings', and energy consumption of natatorium is very large. It's important to choose reasonable air conditioning system according to comfort and energy efficiency demands. At present, the domestic de- sign codes and the standards about natatorium are still not perfect, and there are very few successful cases in China. We try to find out the idea of natatorium air-conditioning energy saving design through tracking monitoring data of a natatorium in Nanjing.for a 3"ear.
出处
《建筑节能》
CAS
2014年第1期9-13,共5页
BUILDING ENERGY EFFICIENCY
关键词
游泳馆节能设计
防结露
节能运行模式
实际运行数据检测
energy-saving design of natatorium
prevention of moisture condensation
energy savingoperation mode
data monitoring of equipment operation