期刊文献+

高频HID灯半桥变压器设计 被引量:1

Design of High Frequency HID Half Bridge Driver Transformer
在线阅读 下载PDF
导出
摘要 半桥变压器是HID灯高频电子驱动电路中的重要器件.文章采用与高频开关电源类似的方法研究了高频HID灯半桥驱动变压器,推导出高频HID灯半桥驱动变压器的初级匝数、高频磁芯的磁隙以及感量等重要参数的计算公式,为该类变压器设计提供依据. A half-bridge transformer is an important device in HID lamp high-frequency electric drive circuit. This articles, using a similar method of frequency switching power supply studies the high-fre- quency half-bridge driver HID lights transformers, high-frequency HID lamp deduced half-bridge driver transformer primary turns , high-frequency magnetic gap and core sense of volume and other important parameters formulas ,provides the basis for the transformer design.
出处 《泉州师范学院学报》 2013年第6期70-74,共5页 Journal of Quanzhou Normal University
基金 泉州市科技项目(2012Z111) 福建省大学生实践基地(S2013011) 福建省大学生创新项目(201310399005)
关键词 高频变压器 半桥驱动 参数计算 transformer half bridgedriver parameter calculation
  • 相关文献

参考文献10

  • 1陈传虞.电子节能与电子镇流器的原理和制造[M]北京:北京人民邮电出版社,2004.
  • 2张乃国.开关电源功率变压器的设计方法[M]北京:清华大学出版社,1996.
  • 3毛兴武;祝大卫.新型电子镇流器的原理与设计[M]北京:北京人民邮电出版社,1999.
  • 4卢小芬.变压器分层绕组模型变焦遗传算法的参数辨识[J].泉州师范学院学报,2005,23(4):24-29. 被引量:1
  • 5PAUL K C,HIRAMOTO T,HORIKAWA Y. Theoretical and experim-enttal investigation of an hid lamp[A].2006.129.
  • 6HUANG C M,LIANG T J,LIN R L. A novel constant power control circuit for HID electronic ballast[J].IEEE Transactions on Power Electronics,2007,(05):1573-1582.doi:10.1109/TPEL.2007.904159.
  • 7MORAIS L M F,DONOSO-GARCIA P F,SELEME S I. Acoustic resonance avoidance in a high pressure sodium lamps via third harmonic injection in a PWM inverter-based electronic ballast[J].IEEE Transactions on Power Electronics,2007,(03):912-918.doi:10.1109/TPEL.2007.896993.
  • 8LIANG T J,HUANG C M,CHEN J F. Two-stage high-power-factor electronic ballast for metal-halide lamps[J].IEEE Transactions on Power Electronics,2009.2959-2966.
  • 9MOO C S,TANGS Y,TSAI W T. Acceleration scenarios of metal halide lamps[J].IEEE Transactions on Plasma Science,2008,(4, part 5):1907-1912.doi:10.1109/TPS.2008.2001192.
  • 10WANG Bin,LI Jun. LOW-cost digitally controlled DC/DC converter for HID electronic ballast[A].2012.2923-2926.

二级参考文献8

  • 1方瑞明.变焦策略的高速异步电机优化设计遗传算法[J].华侨大学学报(自然科学版),2005,26(2):125-129. 被引量:3
  • 2P Werle, Hossein Borsi, Ernst Gockenbach. Transfer Function-Based Partial Discharge Localization in Power Transformers : A Feasibility Study [J]. IEEE Electrical Insulation Magazine. 2002,18 (5): 22- 32.
  • 3P Werle,E Gockenbach, H Borsi. Partial Discharge Measurements on Power Transformers using Transfer Function for Detection and Localization[C]. Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials, 2003. 1154- 1157.
  • 4A Keyhani, H Tsai,S Pillutla,etc. Identification of high frequency transformer model parameters[J],Electric Power Systems Research, 1997, 42 (2) : 127- 133.
  • 5A Keyhani, H Tsai. Maximum likelihood estimation of high frequency machine and transformer winding parameters[J].IEEE Trans. on Power Delivery,1990,5(1)212-219.
  • 6P Pillay,R Nolan,T Haque. Application of genetic algorithms to motor parameter determination for transient torque calculations[J]. IEEE Trans. On Industry Applications,1997,33(5) :1273-1282.
  • 7S M Islam,G Ledwich. Locating transformer faults through sensitivity analysis of high frequency modeling using transfer function approach[C]. Conference Record of the 1996 IEEE international Symposium on electrical insulation, Montel, Quebec, Canada, 1996: 38- 41.
  • 8黄开胜,童怀,郑泰胜,WUQ.H.,TURNERD.R..遗传算法在异步电动机动态模型参数识别中的应用[J].中国电机工程学报,2000,20(8):37-41. 被引量:28

同被引文献9

  • 1WANG Bin,LI Jun.Low-cost digitally controlled DC/DC converter for HID electronic ballast [C].IEEE 7th International Power Electronics and Motion Control Confererme,2012:2923-2926.
  • 2DALLA COSTA N.Electronic ballasts for HID lamps[J].IEEE Ind,2011,17154-59.
  • 3HUANG C M,LIANG T J,LIN R L.A novel constant power control circuit for HID electronic ballast[J].IEEE Trans Power Electron,2007,22:854-862.
  • 4DALLA COSTA N.Microcontroller based high power factor electronic ballast to supply metal halide lamps[J].IEEE Trans,2012,59:1779-1788.
  • 5KAISER W.An alternative optical method for acoustic resorlance detection in HID lamps[J].IEEE Trans,2011,47:1142-1148.
  • 6PAUL K C.Theoretical and experimenter investigation of an hid lamp[C].IEEE Conference Record-Abstracts,2006:129-129.
  • 7WAYMOUTH J F.Metal halide lamps[J].Proceedings of the IEEE,1999,59(4):629-633.
  • 8KEEFFE W M.Recent progress in metal halide discharge-lamp research[J].IEE Proceedings-A,2008,127:181-189.
  • 9LIANG T J,HUANG C M.Two-stage high-power-factor electronic ballast for metal-halide lamps[J].IEEE Trans Power Eleetron,2009,24(12):2959-2966.