期刊文献+

同期房颤双极射频消融对二尖瓣机械瓣膜置换术疗效的影响 被引量:14

暂未订购
导出
摘要 目的 评估同期房颤射频消融对二尖瓣机械瓣膜置换术患者疗效的影响.方法 48例风湿性二尖瓣病变合并心房纤颤患者被纳入研究.根据是否同期进行房颤双极射频消融术分为房颤双极射频消融组(n=26)和单独行二尖瓣置换组(n=22).对围术期相关疗效指标进行对比分析.二尖瓣置换均选用机械瓣膜,同期行三尖瓣成形术45例,左房血栓清除术10例.结果 两组患者无一例死亡,同期行房颤射频消融术组患者与单独行二尖瓣置换组患者相比较,体外循环时间及主动脉阻断时间较长(P〈0.05),但呼吸机辅助呼吸时间、ICU逗留时间及术后住院时间无明显差异(P〉0.05).随访6~21个月,无晚期死亡,同期行房颤射频消融术组患者中3例出现房颤复发,两组患者均未出现血栓栓塞事件;同期行房颤射频消融术组患者左心室射血分数及短轴缩短率较单独行二尖瓣置换组患者明显提高(P〈0.05).结论 二尖瓣机械瓣膜置换同期施行房颤双极射频消融术可明显改善患者的左心功能,其对患者术后早期恢复并无负面影响.
出处 《广东医学》 CAS CSCD 北大核心 2013年第23期3611-3613,共3页 Guangdong Medical Journal
  • 相关文献

参考文献14

  • 1CALKINS H,BRUGADA J,PACKER D L. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation:recommendations for personnel,policy,procedures and follow-up.A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in[J].{H}EUROPACE,2007,(06):335-379.
  • 2GILLINOV A M,SIRAK J,BLACKSTONE E H. The Cox maze procedure in mitral valve disease:predictors of recurrent atrial fibrillation[J].{H}Journal of Thoracic and Cardiovascular Surgery,2005,(06):1653-1660.
  • 3CHAPUT M,BOUCHARD D,DEMERS P. Conversion to sinus rhythm does not improve long-term survival after valve surgery:insights from a 20-year follow-up study[J].{H}European Journal of Cardio-thoracic Surgery,2005,(02):206-210.
  • 4BANDO K,KASEGAWA H,OKADA Y. Impact of preoperative and postoperative atrial fibrillation on outcome after mitral valvuloplasty for nonischemic mitral regurgitation[J].{H}Journal of Thoracic and Cardiovascular Surgery,2005,(05):1032-1040.
  • 5KIM J B,JU M H,YUN S C. Mitral valve replacement with or without a concomitant maze procedure in patients with atrial fibrillation[J].{H}HEART,2010,(14):1126-1131.
  • 6BRYAN A J,ROGERS C A,BAYLISS K. Prospective randomized comparison of CarboMedics and St.Jude Medical bileaflet mechanical heart valve prostheses:ten-year follow-up[J].{H}Journal of Thoracic and Cardiovascular Surgery,2007,(03):614-622.
  • 7CANNEGIETER S C,ROSENDAAL F R. Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses[J].{H}CIRCULATION,1994,(03):635-641.
  • 8EDMUNDS L H. Thrombotic and bleeding complications of prosthetic heart valves[J].{H}ANNALS OF THORACIC SURGERY,1987,(04):430-445.
  • 9MEDI C,HANKEY G J,FREEDMAN S B. Stroke risk and antithrombotic strategies in atrial fibrillation[J].{H}STROKE,2010,(11):2705-2713.
  • 10BANDO K,KOBAYASHI J,HIRATA M. Early and late stroke after mitral valve replacement with a mechanical prosthesis:risk factor analysis of a 24-year experience[J].{H}Journal of Thoracic and Cardiovascular Surgery,2003,(02):358-364.

同被引文献123

  • 1Canale LS,Colafranceschi AS, Monteiro AJ, et al. Use of bipolar radiofrequency for the treatment of atrial fibrilla- tion during cardiac surgery[J]. Arq Bras Cardiol,2011,96 (6) :456-464.
  • 2Cappato R,Calkins H ,Chen SA, et al. Updated worldwidesurvey on the methods, efficacy, and safety of catheter ab- lation for human atrial fibrillation [J]- Circ Arrhythm Electrophysiol, 2010,3 ( 1 ) .. 32-38.
  • 3Tekumit H, Uzun K,Cenal AR, et al. Midterm results of left atrial bipolar radiofrequency ablation combined with a mitral valve procedure in persistent atrial fibrillation[J]. Cardiovasc J Aft,2010,21(3) ..137-141.
  • 4Voeller RK,Zierer A,Lall SC,et al. Efficacy of a novel bi- polar radiofrequeney ablation device on the beating heart for atrial fibrillation ablation: a long-term porcine study [J]. J Thorac Cardiovasc Surg, 2010,140 (1) : 203-208.
  • 5JamiesonWR, Ye J, Higgins J, et a/.Effect of prosthesis- patient mismatch on long-term survival with aortic valve replacement:assessment to 15 years[J].Ann Thorac Surg, 2010,89(1) :51-58.
  • 6Yottasurodom C,Namthaisong K,Porapakkhamp,et a/.Pa- tient-prosthesis mismatch has no influence on in-hospi- tal mortality after aortic valve replacement[J].J Med Assoc Thai, 2012,95(8) : $64-$70.
  • 7Mohammadi H,Mequanint K.Prosthetic aortic heart valves: modeling and design[J].Med Eng Phys, 2011,33 (2): 131-147.
  • 8Sezai A, Shiono M, Akiyama K,et a/.Evaluation of St.Jude Medical valve's long-term function by Doppler echocar- diography[J].Ann Thorac Cardiovasc Surg, 2001,7 (4) : 216-222.
  • 9Wu M,Zhang S,Dong A,et al.Long-term outcome of maze procedure plus valve replacement in treating rheumatic valve disease resulting in atrial fibrillation[J].Ann Thorac Surg,2010,89(6):1942-1949.
  • 10Liu X,Tan HW,Wang XH,et al.Efficacy of catheter ablation and surgical Cryo Maze procedure in patient with long-lasting persistent atrial fibrillation and rheumatic heart disease:a randomized trial[J].Eur Heat,2010,31(21):2633-2641.

引证文献14

二级引证文献60

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部