摘要 基于前向散射能见度仪的工作原理、结构特点及使用环境,分析了前向散射能见度仪的测量误差来源、产生测量误差原因及误差模型,归纳了前向散射能见度仪出厂标定方法、标定参数及标定参数修正方法。为确保能见度观测数据具有准确性,并根据将来量值传递需要,在分析了能见度量值传递参数基础上,提出了前向散射能见度仪的实验室标定条件和方法,梳理了前向散射能见度仪现场光学装置校准、校准板校准及人工校准方法,为今后建立能见度量值传递体系和编写相关校准规范提供参考。 Based on the forward scatter visibility instrument working principle, the structural characteristics, operating environment, measurement error, causes for errors, and the error model of the forward scatter visibility instrument are analyzed. The factory calibration method, calibration parameters, and calibration parameters correction methods of the forward scatter visibility instrument are summed up, according to the needs of dissemination in the future, so to ensure the accuracy of visibility observation data. Based on the transmit parameter analysis of visibility values, the laboratory calibration method and calibration conditions of the forward scatter visibility instrument are put forwarded. The field optical device calibration, calibration plate, and manual calibration methods are discussed, to provide the references for the development of the future dissemination system and the establishment of the related calibration standards.
作者 朱乐坤 李林
出处 《气象科技》 2013年第6期1003-1007,共5页 Meteorological Science and Technology
关键词 前向散射能见度仪 测量误差 校准技术 forward scattering visibility meter measurement error calibration technique
  • 相关文献

参考文献5

  • 1李春亮;曲来世;张勇.能见度测量技术100问[M]{H}北京:气象出版社,20091-244-46.
  • 2中国气象局监测网络司.气象地面观测规范[M]{H}北京:气象出版社,200317-20.
  • 3罗振之;施昌彦;金华章.通用计量术语及定义[M]{H}北京:中国计量出版社,19997-8.
  • 4张玉存.气象仪器试验鉴定技术[M]{H}北京:国防工业出版社,2004168-180.
  • 5施昌彦.测量仪器特性评定指南[M]{H}北京:中国计量出版社,200335-36.

同被引文献158

引证文献31

二级引证文献93

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部