摘要 基于继电保护装置功能测试的需求,以Agilent34980A为主控制器,结合Agilent电源与信号发生器,Omicron等设备,设计并实现了一套硬件测试系统。结合相应的测试软件,对待测装置各硬件回路进行测试。经实际应用,该测试系统稳定,灵活,便于升级。 Based on the necessary of function test on relay devices, a set of the hardware test system is designed and realized by Agilent34980A ( as the main controller) , Agilent power and signal generator and Omicron. Combining with the related test software, the hardware test is conducted. After application, the result shows that the system is stable, flexible and easy to update.