期刊文献+

基于租赁中心平台的急救设备JCI标准化管理研究 被引量:4

Emergency Treatment Equipment JCI Standardization Management Based on Lease Center
暂未订购
导出
摘要 目的:探索租赁中心各急救设备的标准化管理。方法:对医院现今急救设备管理进行自我评估,强化JCI标准持续改进理念,将JCI标准中设备与安全条款与设备质量控制参数检测结合应用于标准化管理。结果:依据自我评估结果及JCI考核要求,制定急救设备风险评定、质量控制检测、数字化管理等持续改进措施。结论:将JCI标准考核要求应用于租赁中心急救设备管理可以促进设备管理措施的改进,推动管理的标准化建设。 Objective To explore the standardized management of emergency treatment equipment in lease center. Methods Self-evaluation of the existing emergency treatment equipment management was performed, and the items related to equipment safety and quality control in JCI standard were introduced into the standardized management. Results Risk evaluation, quality control and detection, digital management and etc of emergency treatment equipment were determined according to the self-evaluation result and JCI requirements. Conolusion The introduction of JCI standard into the management of emergency treatment equipment in lease center contributes to the standardized management of equipment.
机构地区 解放军
出处 《医疗卫生装备》 CAS 2013年第11期114-115,117,共3页 Chinese Medical Equipment Journal
基金 全军军事医学计量科研专项课题(2011-JL3-003)
关键词 租赁中心 急救设备 JCI标准 lease center emergency treatment equipment JCI standard
  • 相关文献

参考文献9

二级参考文献52

共引文献102

同被引文献56

  • 1栗成功.反对重复购置医疗设备、加大共享卫生资源的力度[J].云南大学学报(自然科学版),1997,19(S3):250-251. 被引量:1
  • 2Clark T,Perron E.临床工程指引:医疗仪器设备临床应用分析评估[M].卫生部医院管理研究所,组织翻译.北京:中国计量出版社,2009:5-14.
  • 3唐伟.急救设备质量管理体系构建[J].重庆医学,2007,36(4):378-379. 被引量:26
  • 4Day SW, McKeon IM, Garcia J, et al. Use of Joint Commission International standards to evaluate and improve pediatric oncology nursing care in Guatemala[J].Pediatr Blood Cancer, 2013, 60 (5): 810:5.
  • 5Rizz F, Pizzuto M, Lodetti L, et al.Ouality for home palliative care:an Italian metropolitan multicentre JCI: certified model[J]. BMJ Support Palliat Care, 2012,2(1):57-62.
  • 6Joint Commission Interaational. Joint Commissioin International hccreditation Standards for flospital[M]. 3rd. USh:Publication of Joint Commission Resources, 2007.
  • 7Kreuz J, Batta O, Zimmer S, et al. Detailed electrical analysis of lead failures in a small: scaled right ventricular defibrillator lead:reality of Sprint Fidelis medical device recalls[J]. Hellenic J Cardiol, 2010,51(3):219:25.
  • 8Achkar J, Dowdal J, Fink D, et al. Balloon dilation complication during the treatment of subglottic stenosis: background of the FDA class 1 recall for the 18x40: mm Acclarent Inspira AIR balloon dilation system[J]. Ann Otol Rhinol Larynqol, 2013,122(6):364:8.
  • 9Kramer DB, Xu S, Kesselheim AS. How does medical device regulation perform in the United States and the European union? A systematic review[J]. PLoS Med, 2012,9(7):e10011276.
  • 10刘延武,吕鹏,王卫东,周丹.医学工程质量控制风险评估方法[J].北京生物医学工程,2008,27(2):169-172. 被引量:11

引证文献4

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部