有创呼吸机管路系统不同更换周期与呼吸机相关性肺炎发生的关系 被引量:4

Invasive ventilator piping system replacement cycle with different ventilator associated pneumonia occurred in relation
暂未订购
导出
摘要 目的探讨有创呼吸机管路系统不同更换周期与呼吸机相关性肺炎(VAP)发生的关系,确定适合的机械通气患者呼吸机管路的更换周期。方法选择96例呼吸衰竭需建立人工气道进行机械通气的患者,采取呼吸机管路及湿化装置,分别间隔3、5、7d更换,分为3d组、5d组、7d组,分别对呼吸机管路的集水杯进行采样和细菌学检测,同时观察3d组患者发生VAP的情况。结果 96例患者中共分离出34 096株病原菌,革兰氏阳性菌6 226株(18%),革兰氏阴性菌27 870株(82%),发生VAP 70例(24.31%)。3d组2 183株(6%),革兰氏阳性菌437株(1%),革兰氏阴性菌1 746株(5%),发生VAP 7例(7.29%);5d组7 753株(23%),革兰氏阳性菌1 383株(4%),革兰氏阴性菌6 370株(19%),发生VAP 15例(15.63%);7d组24 160株(71%),革兰氏阳性菌4 406株(13%),革兰氏阴性菌19 754株(58%),发生VAP 48例(50.00%)。7d组VAP的发病率明显高于3d组、5d组,差异有统计学意义(P<0.05),3d组和5d组比较差异无统计学意义。结论呼吸机管路更换时间与VAP发生率相关,建议7d至少更换1次呼吸机管路,可以降低VAP的发生率。 Objective To study the relationship between different replacement cycle of breathing machine pipeline system and ventilator associated pneumonia (VAP), also determine the suitable mechanical venti- lation pipe replacement cycle for patients with ventilator. Methods 96 patients with respiratory failure who need artificial airway to achieve mechanical ventilation used breathing machine line spacing and wet- ting device. The replacement intervals were three days, five days, 7 days respectively. And three groups were established, namely, 3-day group, 5-day group, 7-day group and samples were collected respectively from glasses of breathing machine line set. The bacteriology were observed, and VAP in 3-day group were examined at the same time. Results 34 096 strains of pathogenic bacteria from a total 96 of patients were isolated, with 6 226 strains of gram-positive bacteria accounting for 18%, 27 870 strains of gram-negative bacteria accounting for 82% and 70 cases with VAP, accounting for 72.9% ; 3-day group had 2 183 plants (6 %) with 437 strains of gram-positive bacteria accounting for 1%, 1 746 strains of gram-negative bacteria accounting for 5%, 7 cases with VAP accounting for 7.29%; 5-day group had 7 753 strains accounting for 23%, 1 383 strains of gram-positive bacteria accounting for 4%, 6 370 strains of gram-negative bacteria ac- counting for 19% and 15 cases with VAP accounting for 15.63%; among them 7-day group had 24 160 plants accounting for 71%, 4 406 strains of gram-positive bacteria accounting for 13%, 19 754 strains of gram-negative bacteria accounting for 58% and 48 cases with VAP accounting for 50%. The incidence of VAP in 7-day group was obviously higher than that of 3-day and 5-day groups, the difference was statisti- cally significant (P 〈0.05). There was no significant difference between 3-day group and 5-day group. Conclusion The time of breathing machine pipeline replacement was associated with the incidence of VAP. This study suggests that the breathing machine pipeline should be changed once every 7 days at least, to reduce the incidence of VAP.
出处 《新疆医科大学学报》 CAS 2013年第11期1628-1630,共3页 Journal of Xinjiang Medical University
基金 新疆医科大学科研创新基金(xjc201179)
关键词 机械通气 呼吸机管路 呼吸机相关性肺炎 mechanical ventilation breathing machine pipeline ventilator associated pneumonia
  • 相关文献

参考文献5

  • 1Craven DE, Steger KA, Barber TW. Preventing nosocomial pneumonia state o{ the art and perspectives {or the 1990s[J]. AmJ Med, 1991, 91(3)44.
  • 2Dreyfuss D, Djedaini K, Weber P, et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change[J]. Am Rev Respir Dis, 1991, 143 (4) :738-743.
  • 3Long MN, Wickstrom G, Grimes A, et al. Prospective, ran- domized study o{ ventilator associated pneumonia in patients with one versus three ventilator circuit changes per week[J]. Infect Control Hosp Epidemiol, 1996, 17 ( 1 ) : 14 19.
  • 4侯桂红,李建华,杨秀红.气管切开术后气道管理效果观察[J].新疆医科大学学报,2008,31(7):898-899. 被引量:4
  • 5邹俊宁.呼吸机相关肺炎研究进展[J].中华医院感染学杂志,2002,12(6):478-480. 被引量:80

二级参考文献11

共引文献82

同被引文献46

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部