摘要 冠状动脉(冠脉)造影仍是目前诊断冠心病的“金标准”,但其所提供的二维影像仍不能真实反映血管腔的三维结构。另外,弥漫性病变导致的参考血管节段异常、造影投射角度造成的病变短缩、管腔内斑块的偏心性及造影剂注射充盈不佳等问题均可干扰对冠脉病变的评估。
出处 《国际心血管病杂志》 2013年第6期329-331,共3页 International Journal of Cardiovascular Disease
  • 相关文献

参考文献17

  • 1Jensen LO, Thayssen P, Mintz GS, et al. Comparison of intravascular ultrasound and angiographic assessment of coronary reference segment size in patients with type 2 diabetes mellitus[J]. Am J Cardiol, 2008,101 (5) : 590 595.
  • 2Tobis J, Azarbal B, Slavin L. Assessment of intermediate severity coronary lesions in the catheterization laboratory[J]. J Am Coil Cardiol, 2007,49(8) :839-848.
  • 3Fischer JJ, Samady H, McPherson JA, et al. Comparison between visual assessment and quantitative angiography versus fractional flow reserve for native coronary narrnwings of moderate severity [J]. Am J Cardiol, 2002, 90 (3) : 210-215.
  • 4Kern MJ, Samady H. Current concepts of integrated coronary physiology in the catheterization laboratory[J]. J Am Coll Cardiol, 2010,55(3) : 173-185.
  • 5Takayama T, Hndgson JM. Prediction of the physiologic severity of coronary lesions using 3D IVUS: validation by direct coronary pressure measurements [J]. Catheter Cardiovasc Interv, 2001,53(1) :48-55.
  • 6Abizaid A, Mintz GS, Pichard AD, et al. Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty[J]. Am J Cardiol, 1998,82(4) :423 428.
  • 7Nishioka T, Amanullah AM, Luo H, et al. Clinical validation of intravascular ultrasound imaging for assessment of coronary stenosis severity: comparison with stress myocardial perfusion imaging[J]. J Am Coll Cardiol, 1999,33(7) :1870- 1878.
  • 8Briguori C, Anzuini A, Airoldi F, et al. Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve[J]. Am J Cardiol, 2001,87(2) :136-141.
  • 9Abizaid AS, Mintz GS, Mehran R, et al. Long term follow- up after pereutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions[J] Circulation, 1999, 100(3) : 256-261.
  • 10Takagi A, Tsurumi Y, Ishii Y, et al. Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis : relationship between quantitative ultrasound tomography and pressure derived fractional flow reserve[J]. Circulation, 1999,100(3) :250-255.