期刊文献+

过硫酸钾-儿茶素催化光度法测定铅 被引量:2

Determination of Lead by Catalytic Kinetic Photometry With Potassium Peroxydisulfate-Catechin as Indicative Reaction
在线阅读 下载PDF
导出
摘要 以微型计算机和分光光度计联机用催化光度法测定痕量铅,以过硫酸钾氧化儿茶素作指示反应。在440nm测儿茶素氧化产物的吸光度变化。在pH9.3,K_2S_2O_8和儿茶素浓度分别为0.08和3.75×10^(-4)mol/L时可测0.4μg/ml以下的铅。 With an on-line micro-computer connected to a speetrophotometer, trace amount of lead was determined by catalytic kinetics. The reaction in which catechin is oxidized by potassium peroxydisulfate was used as indicative reacticn. The absorbance change of the oxidation product of catechin at 440 nm was measured, Lead was determined under condition of 0,08 mol/L K_2S_2O_8 and 3.75×10^(-4) mol/L catechin at pH 9. 3. Though Ag^+, Cu^(2+), Cd^(2+), Zn^(2+) and Fe^(3+) interfere, they can be eliminated by masking, when their amount is less than 40, 18, 18, 13 and 13 times of lead respectively, Bi interferes with the determination, when its amount is 4 times of Pb.
机构地区 同济大学化学系
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1991年第3期300-302,共3页 Chinese Journal of Analytical Chemistry
关键词 儿茶素 催化动力学法 测定 Lead, Catalytic kinetics, Photometry, Catechin