摘要 通过实验模拟对低压配电线路电弧故障的特征进行分析研究,采用Mallat算法对低压线路电弧故障电流实施变换,获得各尺度小波变换的小波分量,与正常运行分量相比其故障特征明显,且高尺度的小波分量还可以抑制噪声干扰.为了避免配电线路中负载的启动电流,对电弧故障检测产生可能的误判影响,还对启动电流和电弧故障的小波分量加以比较.研究表明,多尺度小波变换可有效判别电弧故障及区分负载启动电流,在电弧故障检测中具有良好的鲁棒性. The arc fault characteristics in low voltage distribution lines are experimentally researched in this paper. The Mallat algorithm is appointed to transform arc fault signal, the obtained detail com- ponents in different scales are compared to establish characteristic quantity. The results show that arc fault detail components drastically ascend compared to normal current, in addition the high scales de- tail components play part in noise elimination. Eventually the comparison between arc fault current and start current in detail components aimed at avoiding misjudgment shows that Mallat algorithm is effec- tively used to detect arc fault.
出处 《福州大学学报(自然科学版)》 CAS CSCD 北大核心 2013年第5期869-874,共6页 Journal of Fuzhou University(Natural Science Edition)
关键词 低压配电线路 电弧故障 启动电流 小波变换 low -voltage distribution power line arc fault start current wavelet transform
  • 相关文献

参考文献11

  • 1George D, Gray W. The arc -fault circuit interrupter: an emerging product [ J ]. IEEE Transactions on Industry Applications, 1998, 34(5) : 928 -933.
  • 2George D, Kon W, Rober F. More about arc -fault circuit interrupters[ J]. IEEE Transactions on Industry Applications, 2004, 40(4) : 1 006 - 1 011.
  • 3Underwriter Laboratories Inc. UL1699 UL standard for safety for arc -fault circuit -interrupters[ S]. Northbrook:Underwriter Laboratories Inc, 2006.
  • 4Cheng Hong, Chen Xiao -juan, Liu Fang -yun, et al. Series arc fault detection and implementation based on the short -time Fourier transform[ C ]// Power and Energy Engineering Conference. Chengdu : [ s. n. ], 2010:1 -4.
  • 5Ma Shao -hua, Guan Li -na. Arc -fault recognition based on BP neural network [C ]//2011 Third International Conference on Measuring Technology and Mechatronics Automation. Shangshai : [ s. n. ], 2011 : 584 - 586.
  • 6徐贞华.支持向量机的低压故障电弧识别方法[J].电力系统及其自动化学报,2012,24(2):128-131. 被引量:13
  • 7Peng Sun, Xiang Gao. Series arc fault diagnosis technology research based on the analysis of current rate[ C ]//2011 1 st Interna- tional Conference on Electric Power Equipment - switching Technology. Xi' an : [ s. n. ], 2011 : 565 - 568.
  • 8孙鹏,郑志成,高翔.基于小波分析的故障电弧检测方法[J].高压电器,2012,48(1):25-29. 被引量:41
  • 9曹志彤,何国光,陈宏平,E.Ritchie.电机故障特征值的倍频小波分析[J].中国电机工程学报,2003,23(7):112-116. 被引量:52
  • 10曾瑞江,杨震斌,柳慧超.基于小波变换的电力系统谐波检测方法研究[J].电力系统保护与控制,2012,40(15):35-39. 被引量:59

二级参考文献63

共引文献166

同被引文献30

引证文献5

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部