绍兴市部分公共场所集中空调的污染特征 被引量:3

Pollution characteristics of central air condition system in some public places of Shaoxing city
原文传递
导出
摘要 目的了解绍兴市部分公共场所集中空调污染特征及相关人群感染水平。方法根据《公共场所集中空调通风系统卫生规范》,随机抽取绍兴市2006-2010年大型酒店、宾馆、商场、超市、医院、证券公司、写字楼等公共场所的集中空调通风系统和冷却塔水;抽取相应公共场所健康工作人员520人(接触组)和非从事公共场所行业的健康人群(对照组)511人,分别进行卫生学调查和人群血清学检测。结果空调送风中积尘量、细菌总数均值超标,2006年中等污染为70%,严重污染为30%,2010年中等污染为75%,严重污染为25%。2009年110份冷却塔水军团菌检出率为67.3%(74/110),74份水样中分离到90株军团菌,血清型别多样化,但以1型嗜肺军团菌(LP1)为主,同1份水样同时检出2个或3个型别的占总检出水样的17.6%(13/74)。接触组血清中军团菌感染的阳性率为14.9%,对照组4.8%,两组比较,差异有统计学意义。(χ2=23.29,P<0.01)。结论该市公共场所中央空调通风系统微生物污染严重,军团菌广泛存生于公共场所空调冷却塔,血清型别多样化,对人群健康构成潜在威胁,需要引起重视以防军团菌病的暴发流行。 Objective To understand the pollution characteristics of central air condition systems of public places and their infection prevalence among relevant population in Shaoxing city. Methods According to 〈Specifieation for Hygienic Management of Central Air-condition Ventilation System of Public Places〉, central air condition ventilation systems and the water samples from large-scale air-condition cooling towers of public places including grand hotels, shopping centers, hospitals, security exchange and office buildings were chosen in Shaoxing city in 2006-2010 for the test of sanitary condition. A total of 520 healthy staff exposed to this environment was selected for the test of legionella antibody with another 511 from general population as controls. Results The average amount of duct dust, bacteria, and fungi seriously exceeded the national standards. 70% of the central air condition ventilation systems were moderately polluted, and 30% were the severely polluted in 2006. In 2010, 75% were moderately polluted and 250% were severely polluted. In 2009, legionella bacteria were detected in 74 out of 110 samples from water cooling towers, counted up to 67.3%%. Among 74 water samples, 90 legionella bacteria groups were isolated. Serological types were diversified, mainly were legionella pneumophila(LP1). In a total of 74 positive samples, 13 samples, in which 2 or 3 types were simultaneously detected in same one sample, counted up to 17.6% (13/74). The serological prevalence of legionella pneumophila antibodies of the exposed group was 14.87% and that of the control group was 4. 81% (X^2= 23.29, P % 0.01). Conclusions The central air-condition systems in public places of Shaoxing city are severely polluted by micro bacteria, and legionella widely exists in the water from cooling towers. Serological types are diversified which would be the potential threat to the health of population. Close attention should be paid in preventing the outbreak of diseases caused by legionella bacteria.
出处 《工业卫生与职业病》 CAS CSCD 北大核心 2013年第5期269-272,共4页 Industrial Health and Occupational Diseases
基金 绍兴市科技计划项目(2010A23009)
关键词 公共场所 中央空调 污染特征 人群感染 Public places Central air conditionsystem Pollution characteristics Infection to population
  • 相关文献

参考文献8

二级参考文献19

  • 1周铁丽,曹建明,金佩佩,周武.硒酸钠对军团菌生长的影响[J].中华检验医学杂志,2005,28(10):1088-1088. 被引量:1
  • 2斯国静,俞骅,王一泓,吴小辉,杨介钻.杭州市区公共场所空调冷却水中嗜肺军团菌的调查和分析[J].中国卫生检验杂志,2006,16(3):281-282. 被引量:22
  • 3Keller Bw, Hajjeh R,Maria AD, et al. Community outbreak of legionnaires'disease:an investigation confirming the potential for cooling tower haring Legionella species[J].Clin Infect Dis, 1996,22(2):257-261.
  • 4武建国.军团病[M].南京:东南大学出版社,1990.
  • 5Fields B.The molecular ecology of legionellae[J].Trends Microbiol,1996,4(7):286 -290.
  • 6Michael Steinert.Legionella pneumophila:an aquatic microbe goes astray[J].FEMS Microbiology Reviews,2002,26 (2):149-162.
  • 7Edelstein PH,Meyer RD.Legionnaires' disease[J].Chest,1984,85(1):114-120.
  • 8彭晓雯.军团病新发传染病的预防与控制[M].北京:协和医科大学出版社,2002.
  • 9公共场所集中空调通风系统卫生规范[S].2004.
  • 10万超群.军团病防治研究进展[J].疾病监测,1997,12(2):69-71. 被引量:33

共引文献88

同被引文献75

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部