Study on calibration method for the performance index of SPR sensors 被引量:1

Study on calibration method for the performance index of SPR sensors
原文传递
导出
摘要 Aiming at the problem that there isn't any standardized calibration method for the performance index of surface plasmon resonance(SPR) sensor,the calibration method for key performance indices of SPR sensor is summarized and proposed based on the comparison of relative methods and definition of each index.Experimental data of sucrose solutions with various concentrations are obtained by the self-building SPR instrument,and then the calibration method is used to determine the performance indices,such as noise,drift,sensitivity,resolution,linearity,dynamic range and reproducibility.Experimental results show that the definition of indices is reasonable,and the calibration method is correct,which has great significance for performance evaluation of SPR sensor. Aiming at the problem that there isn't any standardized calibration method for the performance index of surface plasmon resonance (SPR) sensor, the calibration method for key performance indices of SPR sensor is summarized and proposed based on the comparison of relative methods and definition of each index. Experimental data of sucrose solutions with various concentrations are obtained by the self-building SPR instrument, and then the calibration method is used to determine the performance indices, such as noise, drift, sensitivity, resolution, linearity, dynamic range and reproducibility. Experimental results show that the definition of indices is reasonable, and the calibration method is correct, which has great significance for performance evaluation of SPR sensor.
出处 《Optoelectronics Letters》 EI 2013年第5期329-332,共4页 光电子快报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.61036012 and 21277118)
  • 相关文献

参考文献21

  • 1J. Homola, Chemical Reviews 108,462 (2008).
  • 2J. Homola, Surface Plasmon Resonance Based Sensors, Springer Verlag, Berlin, 2006.
  • 3C. L. Wong, G. C. K. Chen, X. Li, B. K. Ng, P. Shum, P. Chen, Z. Lin, C. Lin and M. Olivo, Biosensors and Bioelectronics 47,545 (2013).
  • 4J. Liu, B. X. Chen and H. M. Yang, Journal ofOptoelec-tronics?Laser 22,1821 (2011).
  • 5W. Zhang, H. Sun, R. P. Liu, Z. Yue, C. Wang, S. J. Chang, W. D. Geng and G H. Liu, Journal of Optoelectronics? Laser 23,1005 (2012).
  • 6T. M. Chinowsky, M. S. Grow, K. S. Johnston, K. Nelson, T. Edwards, E. Fu and P. Yager, Biosensors and Bioe-lectronics 22, 2208 (2007).
  • 7T. M. Chinowsky, S. D. Soelberg, P. Baker, N. R. Swanson, K. Peter, A. Mactutis, M. S. Grow, R. Atmar, S. S. Yee and C. E. Furlong, Biosensors and Bioelectronics 22, 2268 (2007).
  • 8G. D. VanWiggeren, M. A. Bynum, J. P. Ertel, S. Jeffer-son, K. M. Robotti, E. P. Thrush, D. M. Baney and K. P. Killeen, Sensors and Actuators B: Chemical 127, 341 (2007).
  • 9S. Y. Zhan, X. P. Wang and Y. L. Liu, Measurement Science and Technology 22,025201 (2011).
  • 10A. Giorgini, S. Avino, P. Malara, G Gagliardi, M. Casalino, G Coppola, M. Iodice, P. Adam, K. Chadt, 1. Homola and P. De Natale, Optics Letters 38,1951 (2013).

同被引文献15

  • 1Hu Z L,Gui J B,Zou J,et al. Geometric Calibration of a micro-CT system and performance for insect imaging[J]. IEEE Transactions on Information Technology in Biomedi- cine, 2011,15(4) : 655-660.
  • 2Patel V, Chityala R N, Hoffmann K R, et al. Self-calibration of a cone-beam micro-CT system[J]. Medical. Physics, 2009,36(1) :48-58.
  • 3Xu J Y,Tsui B. A graphical method for determining the in- plane rotation angle in geometric calibration of circular cone-beam CT system[J]. IEEE Transactions on Medical Imaging, 2012,31(3) :825-833.
  • 4Feldkamp L A, Davis L C, Kress J W. Practical cone- beam algorithm[J]. Journal of the Optical Society of A- merica,1984,6(1): 612-619.
  • 5Jiang Hsich. Computed tomography: principle, design, ar- tifacts and recent advances [M]. Second Edition. New York :Wiley, 2006,118-172.
  • 6Liu Y,Gui Z G. A statistical iteration approach with ener- gy minimization to sinogram noise reduction for low-dose X-ray CT[J]. Optik-lnternational Journal for Light and E- lectron Optics,2012,123(23) :2174-2178.
  • 7Robert N, Watt K N, Mainprize J G. The geometric cali- bration of cone-beam systems with arbitrary geometry [J]. Physics in Medicine and Biology, 2009,24 (54): 7239-7261.
  • 8TAN Sheng-qi, CONG Peng, LIU Xi-ming, et al. An interval subdividing based method for geometric calibration of cone-beam CT[J]. NDT & E International, 2013,58 : 49- 55.
  • 9XU Jing-yan,Benjamin M,Tsui W. A graphical method for determining the in-plane rotation angle in geometric cali- bration of circular cone-beam CT systems [J]. IEEE Transactions on Medical Imaging,2012,31(3) :825-833.
  • 10Xu Y,Li H,Yan H,et al. Evaluation of impacts of two as- sumptions in cone beam CT geometry calibration[J]. Medical Physics, 2013,40(6):125.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部