摘要 The urgency of increasing energy efficiency in new building design and retrofits has pushed lighting simulation to play a central role in sustainable lighting design. The shape of the building and its orientation, the reflectances of building surfaces and glazed areas are important parameters in the daylighting design of buildings. Glazing systems can cut energy consumption and associated pollution sources, reduce peak demand, enhance daylighting performance and improve occupant comfort. This paper presents the results of a numerical and experimental comparison between the performances of an office building with and without external sunscreens. The aim was to analyse the illuminance distribution and some investigations have also been made with regards to the effect on daylight in rooms when sunscreens are used. The experimental results were obtained using an office building scale model and sky simulator. The numerical results were obtained through radiance, the ray-tracing program, to accurately predict the light levels and produce photo realistic images of the architectural space in all sky conditions: Illuminance values were obtained respectively through reference point measurements. The daylighting performances of the office building model with and without the sunscreens have been compared and analysed.
出处 《Journal of Energy and Power Engineering》 2013年第6期1040-1046,共7页 能源与动力工程(美国大卫英文)
关键词 DAYLIGHTING office building SUNSCREEN artificial sky radiance. 采光性能 办公楼 数值分析 实验 能源利用效率 照明设计 建筑设计 数值模拟
  • 相关文献

参考文献15

  • 1D.H.W. Li, E.K.W. Tsang, An analysis of daylighting performance for office building in Hong Kong, Building and Environment 43 (2008) 1446-1458.
  • 2G. Editorial, Daylighting-light, form and people, Energy and Buildings 38 (2006) 715-717.
  • 3M. Paroncini, B. Calcagni, F. Corvaro, Daylight factor prediction in atria building designs, Solar Energy 76 (2004) 669-682.
  • 4M. Paroncini, M.M.D.E. Padova, G. Nardini, The comparison between numerical and experimental values of an atrium building, in: 5th International Conference on Sustainable Energy Technologies, SET2006, 2006.
  • 5S. Daryanani, Design consideration for daylighting of new commercial buildings, Energy and Buildings 6 (2) (1984) 109-118.
  • 6C.F. Reinhant, O. Walkenhorst, Validation of dynamic Radiance-based daylight simulations for a test office with external blinds, Energy and Building 33 (2001) 683-697.
  • 7J. Christoffersen, E. Petersen, K. Johsens, O. Valbojom, S. Hygge, Vinduer og dagslys—en feltundersogelse i kontorbygninger (Windows and daylight-a field investigation in office buildings), SBI-rapport, 318, Danish Building Research Institute, Denmark, 1999.
  • 8L. Heschong, Windows and Offices: A Study of Office Worker Performance and the Indoor Environment, Technical report, California Energy Comission, Oct.2003.
  • 9M. Bodert, A. Deneyer, A Guide for the Building of Daylight Scale Models, PLEA, 2006.
  • 10C.L. Cheng, C.L. Chen, C.P. Chou, A mini-scale modeling approach to natural design daylight utilization in building design, Building and Environment 42 (2007) 372-384.