导出
摘要 目的:探讨超声造影在颈部肿大淋巴结性质鉴别诊断中的应用价值。方法:选取97例颈部淋巴结肿大患者的97个颈部肿大淋巴结进行超声检查。先行常规高频彩色多普勒超声检查,然后进行超声造影,观察淋巴结的超声造影表现,将常规彩色多普勒和超声造影结果与病理结果进行比较分析。结果:超声造影判定颈部肿大淋巴结恶性的敏感度为84%(48/58),特异度87%(33/39),准确率83%(81/97)。常规彩色多普勒判定颈部肿大淋巴结恶性的敏感度为72%(42/58),特异性度41%(16/39),准确率为60%(58/97)。结论:超声造影后的灌注显像特征能为颈部肿大淋巴结的鉴别诊断提供有价值的依据。超声造影对颈淋巴结的鉴别诊断准确率明显高于二维彩色多普勒。 Objective:To investigate the application value of the contrast-enhanced ultrasound in differential diagnosis of the cervical tumescent lymph nodes. Methods: 97 cases with cervical tumescent lymph nodes were inspected and made out diagnosis by 2D color Doppler and contrast-enhanced ultrasound. Then surgical excision guided by uhrasonography and pathological examination of these tu- mescent lymph nodes were executed. Results: The sensitivity of the CEUS was 84% , the specificity was 87% and the accuracy was 83%. The sensitivity of the conventional techniques was 58% , the specificity was 54% and the accuracy was 61%. Conclusion: The perfusion characteristics of the cervical lymph nodes can provide important value to differential diagnosis of the cervical tumescent lymph nodes. With conventional sonography and contrast - enhanced ultrasound, we can do better in differentiations of the cervical tu- mescent lymph nodes.
出处 《川北医学院学报》 CAS 2013年第4期354-358,共5页 Journal of North Sichuan Medical College
基金 四川省科技厅支撑项目(2012SZ0072)
关键词 颈部肿大淋巴结 超声检查 造影剂 Cervical lymph nodes Ultrasound Contrast agent
  • 相关文献

参考文献4

二级参考文献19

  • 1洪玉蓉,刘学明,张闻,莫国强,许俊,魏红权.超声造影在浅表淋巴结疾病鉴别诊断中的应用研究[J].中华超声影像学杂志,2006,15(11):849-852. 被引量:77
  • 2Rubaltelli L, Corradin S, Dorigo A, et al. Automated quantitative evaluation of lymph node perfusion on contrast-enhanced sonography. Am J Roentgenol, 2007,188 : 977-983.
  • 3Moritz JD,Iudwig A, Oestmann JW, et al. Contrast-enhanced color Doppler sonography for evaluation of enlarged cervical lymph nodes in head and neck tumors. Am J Roentgenol,2000,174:1279-1284.
  • 4Ying M, Ahuja AT, Brook F. Accuracy of sonographic vascular features in differentiating causes of cervical lymphadenopathy. Ultrasound Med Biol, 2004,30 : 441- 447.
  • 5Esen G. Ultrasound of superficial lymph nodes. Eur J Radiol, 2006, 58 : 345-359.
  • 6Song HP, Yu M, Zhang J, et al. Hemostasis of active bleeding from the liver with percutaneous microwave coagulation therapy under contrast enhanced ultrasonographic guidance: an experimental study. J Ultrasound Med, 2008,27 : 867-874.
  • 7DeVita VT Jr, Serpick AA, Carbone PP. Combination chemotherapy in the treatment of advanced Hodgkin's sdisease[J]. Ann Intern Med ,1970,73(6):881 - 895.
  • 8Quaia E, Calliada F, Bertolotto M, et al. Characterization of focal liver lesions with contrast specific US modes and a sulfur hexafluoride-filled microbubble contrast agent: diagnostic performance and confidence[J]. Radiology, 2004,232(2) :420-430.
  • 9ChoiSH, kono Y, Corbeil J, et al. Model to quantify lymph node enhancement on indirect sonographic lymphography[J]. Am J Roentgenol, 2004,183(2): 513-517.
  • 10Ahuja A,Ying M.Sonography of neck lymph nodes.Part Ⅱ:abnormal lymph nodes.Clin Radiol,2003,58:359-366.

共引文献111

同被引文献44

  • 1洪玉蓉,刘学明,张闻,莫国强,许俊,魏红权.超声造影在浅表淋巴结疾病鉴别诊断中的应用研究[J].中华超声影像学杂志,2006,15(11):849-852. 被引量:77
  • 2洪玉蓉,刘学明,张闻,莫国强,许俊.超声造影定量分析在浅表淋巴结疾病鉴别诊断中的应用[J].中国超声医学杂志,2007,23(3):212-214. 被引量:33
  • 3Stramare R,Scagliori E,Mannucci M,et al. The role of contrastenhanced gray-scale uhrasonography in the differ- ential diagnosis of superficial lymph nodes [J]. Ultrasound Q,2010,26(1):45-51.
  • 4Song HP,Yu M,Zhang J,et al. Hemostasis of active bleeding from the liver with percutaneous microwave coag- ulation therapy under contrast-enhanced uhrasonographic guidance:an experimental study [J]. J Ultrasound Med, 2008,27 : 867-874.
  • 5Rubahelli K,Khadivi Y,Tregnaghi A,et al.Evaluation of lymph node perfusion using continurmis mode harmonic ultrasonography with a second-generation contrast agent[J]. J Ultrasound Med, 2004,23(6) : 829-836.
  • 6Na DG,Lim HK,Byun HS,et al.Differential diagnosis of cervical lymphadenopathy:usefulness of color Doppler sonography[J].Am J Roentgenol, 1997,168(5) : 1311-1316.
  • 7Giovagnorio F,Drudi FM,Fanelli G,et al. Fatty changes as a misleading factor in the evaluation with ultrasound of superficial lymph nodes[J]. Ultrasound Med Biol,2005,31 (8) : 1017 -1022.
  • 8Zenk J,Bozzato A,Hornung J,et al. Neck lymph nodes: prediction by computer-assisted ontrast medium analysis [J]. Ultrasound Med Biol, 2007,33(2) : 246-253.
  • 9Steppan I, Reimer D, Muller-Holzner E, et al.Breast cancer in women:evaluation of benign and malignant axillary lymph nodes wish contrast-enhanced ultrasound[J].Uhra- schall Med, 2010,31 (1) : 63-67.
  • 10Rubaltelli L, Corradin S, Dorigo A,et al. Automated quan- titative evaluation of lymph node perfusion on eontrasten- hanced sonography[J]. Am J Roentgenol, 2007,188 (4) : 977-983.

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部