摘要 为了研究并掌握上海天然气管道主干网9标杂散电流干扰情况以及采取的相关保护措施,采用远程遥测设备监测燃气管道杂散电流干扰规律,同步测试了土壤电位梯度及管地电位。结果表明,地铁锦秋路维修基地泄漏电流是导致上海高压天然气管道9标管道杂散电流腐蚀的干扰源。现场检测了维修基地的相关电力装置性能,包括铁轨轨地电位、轨道绝缘情况、接地装置等,分析了地铁维修基地杂散电流的形成原因并提出了建议措施,包括加强铁轨绝缘施工与管理、加强变电站接地极的检测与管理以及对地极周边埋地管道采取排流保护等。 In order to study and master the condition of the stray current of natural gas 9 section pipeline in Shanghai and take corresponding measures the impact of stray current on gas pipeline was monitored using remote measurement system. The cathodic protection potential and the magnitude of potential gradient on ground surface were simultaneous measured. The results indicate that the current leakage in the Jinqiu road subway maintenance base was the interference source of stray current upon Shanghai high-pressure natural gas 9 section pipeline. The rail potential, grounding, track to earth insulation and overhead power line were also tested. The causes for the current leakage in the subway maintenance base were analyzed, and protective countermeasures were proposed based on the measured results. The countermeasures inclucle to reinforce the construction and management of the rail insulation, the testing and measurement of the grounding electrode in the transformer substation, and the drained current protection.
出处 《腐蚀与防护》 CAS 北大核心 2013年第8期739-742,共4页 Corrosion & Protection
关键词 地铁维修基地 杂散电流 远程遥测技术 同步测试 subway maintenance base stray current remote measurement simultaneous measure
  • 相关文献

参考文献8

二级参考文献25

  • 1马永儒.基于虚拟仪器技术的杂散电流监测系统[J].城市轨道交通研究,2005,8(2):77-78. 被引量:3
  • 2孙军溪,焦金红,徐东.城市轨道交通杂散电流及轨道对地绝缘测试[J].城市轨道交通研究,2006,9(10):66-68. 被引量:9
  • 3马洪儒.北京地下铁道的杂散电流腐蚀与防护[J].城市轨道交通,1990,(1):11-19.
  • 4秦国治,丁量棉,田志明.管道防腐蚀技术[M].北京:化学工业出版社,2004.
  • 5Zakowski K K, Sokolski W. 24-hour characteristic of interaction on pipelines of stray currents leaking from tram tractions[J]. Corrosion Science, 1999,41 (11) : 2103-2108.
  • 6Luca Ardizzon, Paolo Pinato, Dario Zaninelli. Electric traction and electrolytic corrosion: a software tool for stray current calculation[C]//2003 IEEE PES Transmission and Distribution Conference and Exposition, Dallas TX USA: 2003 : 550-551.
  • 7Levin S I, Kharionovsky V V. Causes and frequency of failures on gas mains in the USSR PIPE[J].Pipes Pipelines International, 1993,38(4) : 7-8.
  • 8Ian Cotton, Pete Aylott, Petra Ernst. Stray current control in DC mass transit systems[J]. IEEE Rransaction on Vehicular Technology March, 2005, 54 (2) 722.
  • 9SYJ4020-1988.埋地钢质管道石油沥青防腐层施工及验收规范[S].
  • 10Darowicki K, Krakowiak S, Slepski P. Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy [J].Electrochimica, 2004, 49 (17):2909-2918.

共引文献960

同被引文献213

引证文献26

二级引证文献170

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部