摘要 [目的]建立应用高效液相色谱、紫外检测器同时测定植物样品中花青素的测定方法。[方法]样品采用乙醇酸性水溶液(乙醇∶水∶盐酸=3∶1∶1)振荡,超声提取,沸水浴水解,用高效液相色谱紫外检测器测定。流动相A为浓度1%甲酸水溶液,流动相B为浓度1%甲酸乙腈溶液,流速0.8 ml/min,检测波长530 nm。[结果]样品添加回收率为75.7%~92.7%,方法精密度为2.7%~6.3%,当浓度为1~200μg/ml时峰面积与浓度呈线性关系,最低检出限为0.03~0.11 mg/kg,最低定量限为0.10~0.35 mg/kg。[结论]该方法简便快速,稳定性好,可作为植物样品中花青素测定的有效方法。 [ Objective] The research aimed to establish the simultaneous determination method for the anthocyanins in plant samples by high performance liquid chromatography/UV detector. [ Method] Sample was extracted with ethanol in acidic aqueous solution( V(C2HsOH) : V ( H2 O) : V(HC1) = 3:1 : 1 ) and ultrasonic extraction, boiling hydrolysis, under mobile phase A of 1% HCOOH, B of 1% HCOOH - CH3 CN, v of 0.8 ml/min,A of 530 nm. It was detected by UV-HLPC. [ Result] Sample addition recovery was 75.7% -92.7%. Method precision was 2.7% - 6.3%. There was a linear relationship between the peak area and the concentration at the concentration range of 1 - 200 μg/ml. The minimum detection limit was 0.03 -0.11 mg/kg,and the minimum quantitation limit was 0. 10 -0.35 mg/kg. [ Conclusion] The method was simple,rapid and stable,which could be used as an effective method to determine the anthocyanin in plant samples.
作者 刘红 徐科
出处 《安徽农业科学》 CAS 2013年第14期6123-6124,共2页 Journal of Anhui Agricultural Sciences
基金 黔科合SY字[2011]3128
关键词 植物样品 花青素 高效液相色谱 Plant samples Anthocyanin High performance liquid chromatography