摘要
对 110kV仿日立电力变压器的安匝分布及短路机械力进行了全面的计算 ,介绍了广州电力设备厂新制仿日立电力变压器的结构特点及针对抗短路冲击能力的强化措施 ,并就相关问题提出了一些个人看法 ,最后介绍了在运行的变压器的现场加固方法并作了简单分析。
Based on the calculation of ampere turn distribution and short circuit mechanical force of 110 kV H type transformers, the structural features of H type transformers newly manufactured by Guangzhou Electric Power Equipment Plant and the intensive measures for improving their ability to withstand short circuit impact are described with suggestions on relative problems put forward. The method to strengthen the on stream transformers on site is introduced and analyzed as well.
出处
《广东电力》
2000年第4期18-20,45,共4页
Guangdong Electric Power
关键词
电力变压器
抗短路
计算
强化措施
H type transformer
short circuit withstand
computation
intensive measures