期刊文献+

Hank's人工模拟体液中碳离子注入TAMZ合金缝隙腐蚀行为 被引量:1

Corrosion behavior of TAMZ alloy crevice samples implanted by carbon ion in Hank's artificial simulated body fluids
原文传递
导出
摘要 在人体模拟体液Hank’s溶液中对碳离子注入TAMZ合金缝隙试样的缝隙腐蚀行为进行研究.结果表明,随着Hank’s溶液中pH值的减小,注入碳离子TAMZ合金缝隙试样的阳极电流密度增大,促进了合金缝隙腐蚀历程.Hank’s溶液中电化学测试结果表明:注入碳离子TAMZ合金缝隙试样的腐蚀电位升高、阳极极化电流密度降低,改善了电化学性能.这是由于碳离子注入后形成了碳化物的无序层膜,抑制了合金的活性溶解,提高了合金的耐缝隙腐蚀性能. Corrosion behavior of TAMZ alloy crevice samples im- planted by carbon ion is studied in Hank' s artificial body fluids. Results show that anodic current density of TAMZ alloy crevice samples implanted by carbon ion increase with decreasing of pH value in Hank' s solution, which accelerates the crevice corro- sion. The electrochemical tests prove that the corrosion potential of the implanted samples move toward positive and the anodic po- larized current density is reduced, which result in improving its electrochemical characteristic. It is due to an unordered carbide film formed on the surface of TAMZ alloy crevice samples after implantation, which blockes alloy element actively dissolving and enhances crevice corrosion resistance of the alloy.
出处 《大连海事大学学报》 CAS CSCD 北大核心 2013年第2期108-111,115,共5页 Journal of Dalian Maritime University
基金 国家高技术研究发展计划(863)资助项目(2009AA05Z120)
关键词 碳离子注入 TAMZ合金 Hank’s人工模拟体液 缝隙腐蚀行为 carbon ion implantation TAMZ alloy Hank' s arti- ficial body fluids crevice corrosion behavior
  • 相关文献

参考文献5

二级参考文献29

  • 1R.B. Song, Y.L. Kang, J.L. Sun, A.M. Zhao and W.M. Mao School of Materials Science & Engineering, University of Science & Technology Beijing, Beijing 100083,China.MICROSTRUCTURE EVALUATION OF SEMI-SOLID STEEL MATERIALS IN ROLLING PROCESS AND THE RESULTING MECHANICAL PROPERTIES[J].Acta Metallurgica Sinica(English Letters),2001,14(5):347-351. 被引量:21
  • 2张玉梅 郭天文 李佐臣.Rare Metal Materials and Engineering (稀有金属材料与工程)[J],1999,28(2):125-125.
  • 3Henry JC, Damron TA, Weiner MM, et al. Biomechanical analysis of humeral diaphyseal segmental defect fixation. Clin Orthop, 2002,(396): 231
  • 4Christion Gaebler, Stefanie Stanzl- Tschegg, Laube W. et al. The fatigue strength of small diameter tibia nail. Injury, 2001, 32:401
  • 5Gorczyca JT, McKale T, Pugh K, et al. Modified tibial nails for treating distal tibia fractures. J Orthop Trauma, 2002, 16 (1): 18
  • 6Robert J, Thomas R. Immediate weight bearing after treatment of a comminuted fracture of the fracture of femoral shaft with a statistically locked intramedullary nail. J Bone Joint Surg, 1999, 81 (11): 15
  • 7伍本德,稀有金属材料与工程,1988年,4期,51页
  • 8付涛.Rare Metal Materials and Engineering(稀有金属材料与工程)[J],2003,32(2):137-137.
  • 9Cooper J R, Dowson D, Fisher J. Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene [J]. Wear, 1993, 162/164(part 1): 378-384.
  • 10Krzypow D J, Timnacc M. Cyclic steady state stress- strain behavior of UHMW polyethylene [J]. Biomaterials, 2000, 21(20) : 2081-2087.

共引文献40

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部