期刊文献+

Diffusion tensor imaging fiber tracking with reliable tracking orientation and flexible step size

在线阅读 下载PDF
导出
摘要 We propose a method of reliable tracking orientation and flexible step size fiber tracking.A new directional strategy was defined to select one optimal tracking orientation from each directional set,which was based on the single-tensor model and the two-tensor model.The directional set of planar voxels contained three tracking directions:two from the two-tensor model and one from the single-tensor model.The directional set of linear voxels contained only one principal vector.In addition,a flexible step size,rather than fixable step sizes,was implemented to improve the accuracy of fiber tracking.We used two sets of human data to assess the performance of our method;one was from a healthy volunteer and the other from a patient with low-grade glioma.Results verified that our method was superior to the single-tensor Fiber Assignment by Continuous Tracking and the two-tensor eXtended Streamline Tractography for showing detailed images of fiber bundles.
出处 《Neural Regeneration Research》 SCIE CAS CSCD 2013年第16期1481-1490,共10页 中国神经再生研究(英文版)
基金 supported by the Science and Technology Commission of the Shanghai Municipality of China,No.10dz2211800,No.10XD1421400 the National High Technology Research and Development Program,No.2009AA02Z415 the Innovation Program of Shanghai Municipal Education Commission,No.11yz292
  • 相关文献

参考文献29

  • 1Vargas MI, Viallon M, Nguyen D, et al. Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions. Neuroradiology. 2010;52(3):237-245.
  • 2Mori S, van Zijl PC. Fiber tracking: principles and strategies-a technical review. NMR Biomed. 2002;15(7-8):468-480.
  • 3Jiang H, van Zijl PC, Kim J, et al, DtiStudio: resource program for diffusion tensor computation and fiber bundle tracking. Comput Methods Programs Biomed. 2006;81(2): 106-116.
  • 4Behrens TE, Woolrich MW, Jenkinson M, et al. Characterization and propagation of uncertainty in diffusion-weighted MR imaging. Magn Reson Med. 2003;50(5): 1 077-1088.
  • 5Behrens TE, Berg HJ, Jbabdi S, et at, Probabilistic diffusion tractography with multiple fibre orientations: What can we gain? Neuroimage. 2007;34(1 ):144-155.
  • 6Zhang F, Hancock ER, Goodlett C, et at. Probabilistic white matter fiber tracking using particle filtering and von Mises-Fisher sampling. Med Image Anal. 2009;13(1 ):5-18.
  • 7Nimsky C, Ganslandt 0, Hastreiter P, et al, Preoperative and intraoperative diffusion tensor imaging-based fiber tracking in glioma surgery. Neurosurgery. 2005;56(1): 130-137.
  • 8Setzer M, Murtagh RD, Murtagh FR, et al, Diffusion tensor imaging tractography in patients with intramedullary tumors: comparison with intraoperative findings and value for prediction of tumor resectability. J Neurosurg Spine. 2010; 13(3):371-380.
  • 9Wang YX, Zhu XL, Deng M, et al, The use of diffusion tensor tractography to measure the distance between the anterior tip of the Meyer loop and the temporal pole in a cohort from Southern China. J Neurosurg. 2010;113(6): 1144-1151.
  • 10Buchmann N, Gempt J, Stoffel M, et al, Utility of diffusion tensor-imaged (DTI) motor fiber tracking for the resection of intracranial tumors near the corticospinal tract. Acta Neurochir (Wien). 2011 ;153(1 ):68-74.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部