摘要
首先分析了开关柜内部故障电弧产生的原因及危害,进而介绍了目前常用的开关柜内部故障电弧的检测技术,最后分析并阐述了一种开关柜内部故障电弧检测保护装置的工作原理及应用价值。
参考文献4
-
1张瑞祥,耿英三,宋政湘,徐斌.开关柜故障电弧检测与预警方法的新进展[J].电气制造,2012(7):36-38. 被引量:9
-
2蓝会立,张认成.开关柜内部故障电弧探测法的研究现状及趋势[J].高电压技术,2008,34(3):496-499. 被引量:39
-
3汪金刚,林伟,王志,李健,何为,王平.基于紫外检测的开关柜电弧在线检测装置[J].电力系统保护与控制,2011,39(5):128-133. 被引量:29
-
4蔡彬,陈德桂,吴锐,王鑫伟,高冬梅,陈卫国.开关柜内部故障电弧的在线检测和保护装置[J].电工技术学报,2005,20(10):83-87. 被引量:80
二级参考文献51
-
1蔡彬,陈德桂,吴锐,王鑫伟,高冬梅,陈卫国.开关柜内部故障电弧的在线检测和保护装置[J].电工技术学报,2005,20(10):83-87. 被引量:80
-
2方志,邱毓昌,王辉.介质阻挡放电的放电过程仿真研究[J].高电压技术,2006,32(8):62-65. 被引量:15
-
3Kalkstein E W,Doughty R L,Paullin A E,et al.Safety benefits of arc-resistant metal clad medium voltage switch gear[J].IEEE Translations on Industry Application,1995,31 (6):1402-1410.
-
4Klaus D W,Balnaves D.Internal faults in distribution switchgear-where are we now and where are we going[C].//Trends in Distribution Switchgear,Conference Publication No.459 IEE.1998:68-72.
-
5Sidhu T S,Singh G,Saehdev M S.Protection of power system apparatus against arcing faults[C].//1998 IEEE Region 10th Intemational Conference on Global Connectivity in Energy,Computer,Communication and Control.1998:436-439.
-
6Sidhu T S,Sachdev M S,Sagoo G S.Detection and location of low-level arcing faults in metal-clad electrical apparatus[C].//Developments in Power System Protection,Conference Publication No.479 IEE.2001:157-160.
-
7Sidhu T S,Sagoo G S,Sachdev M S.Multi-sensor secondary device for detection of low-level arcing faults in metal-clad MCC switchgear panel[J].IEEE Transactions on Power Delivery,2002,17(1):129-134.
-
8Nakano S,Tsubaki T,Hironaka S.Applying a voice recognition system for SF6 gas insulated switchgear's inspection/maintenance services[J].IEEE Transactions on Power Delivery,2001,16 (4):534-538.
-
9Sidhu T S,Sagoo G S,Sachdev M S.On-line detection of low-level arcing faults in metal-clad electrical apparatus.Electrical and Computer Engineering,2000 Canadian Conference,2000:730-734.
-
10Jungang Liu,Wei He,Liang Zhou,et al.Application of Ultraviolet Detector in Discharge Detection,International Journal of Emerging Electric Power Systems:Vol.7:No.3,Article 2[EB/OL].http://www.bepress.com/ijeep/voll 7/iss3/art2.
共引文献129
-
1唐圣学,刁旭东,陈丽,张继欣,姚芳.光伏发电系统直流串联微弱故障电弧检测方法研究[J].仪器仪表学报,2021,42(3):150-160. 被引量:36
-
2龚优华,安海光,李赵华.电弧光保护系统在风力发电场集电母线保护中的应用[J].内蒙古石油化工,2014,40(4):37-38. 被引量:1
-
3杨建红,张认成,房怀英.Duffing振子信号探测在故障电弧短路保护中的应用[J].电力系统自动化,2006,30(24):69-72. 被引量:12
-
4杨建红,张认成,杜建华.基于多信息融合的故障电弧保护系统的应用研究[J].高压电器,2007,43(3):194-196. 被引量:16
-
5蓝会立,张认成.开关柜内部故障电弧探测法的研究现状及趋势[J].高电压技术,2008,34(3):496-499. 被引量:39
-
6杨建红,张认成,房怀英.Lyapunov指数法在故障电弧早期探测中的应用[J].电工电能新技术,2008,27(2):55-58. 被引量:9
-
7蓝会立,张认成.开关柜内部弧光短路伴生弧声的频谱特性研究[J].高压电器,2008,44(2):107-109. 被引量:15
-
8杨建红,张认成,房怀英.关联维数在故障电弧早期探测和保护中的应用[J].低压电器,2008(17):5-8. 被引量:1
-
9杨建红,张认成,黄宜坚,房怀英.基于高阶谱估计故障电弧早期信息特征提取[J].淮阴工学院学报,2008,17(5):47-50. 被引量:4
-
10何佳英.电弧光保护在发电厂厂用电系统中的应用[J].科技资讯,2009,7(2):150-151.
同被引文献14
-
1蔡彬,陈德桂,吴锐,王鑫伟,高冬梅,陈卫国.开关柜内部故障电弧的在线检测和保护装置[J].电工技术学报,2005,20(10):83-87. 被引量:80
-
2Guo Yunmei, Wang Li, Wu Zhuoqi, et al. Wavelet packet analysis applied in detection of low- voltage DC arc fault[C]. Industrial Electrical and Applications, 2009:4013-4016.
-
3Yao Xiu, Luis Herrera, Wang Jin. A Series DC arc fault detection method and hardware implementation[C]. IEEE Conference Publications, 2015:2444-2449.
-
4Yao Xiu, Herrera L, Characteristic study wavelet transform bas an ed Ji d ti hyb Shengchang, et al me rid domain -discrete detection of series DC arc faults[J]. IEEE Journals & Magazines, 2014, 29(6): 3103-3115.
-
5Momoh J A, Button R. Design and analysis of aerospace DC arcing faults using fast fourier transformation and artificial neural network[C] Power Engineering Society General Meeting, 2003 788-793.
-
6Schimpf F, Norum L E. Recognition of electric arcing in the DC-wiring of photovoltaic systems[C] Telecommunications Energy Conference, 2009 1-6.
-
7Charles Luebke, Tom Pier, Birger Pahl, et al. Field test results of DC arc fault detection on residentialand utility scale PV arrays[C]. Photovoltaic Specialists Conference, 2011:1832-1836.
-
8Jay Johnson, Birger Pahl Photovoltaic DC arc fault national laboratories[C]. , Charles Luebke, et al. detector testing at sandia Photovoltaic Specialists Conference, 2011 : 3614-3619.
-
9Jay Johnson, Kenneth Armijo. Parametric study of PV arc fault generation methods and analysis of conducted DC spectrum[C]. Photovoltaic Specialists Conference, 2014:3543-3548.
-
10汪金刚,林伟,王志,李健,何为,王平.基于紫外检测的开关柜电弧在线检测装置[J].电力系统保护与控制,2011,39(5):128-133. 被引量:29
二级引证文献14
-
1唐圣学,刁旭东,陈丽,张继欣,姚芳.光伏发电系统直流串联微弱故障电弧检测方法研究[J].仪器仪表学报,2021,42(3):150-160. 被引量:36
-
2王希彬,戴洪德,肖楚琬,赵志坚.飞机EWIS电弧故障检测技术综述[J].系统仿真技术,2020(3):195-201. 被引量:3
-
3郭凤仪,刘大卫,王智勇,邓勇,田东豪,游江龙,冯晓丽.光伏系统直流故障电弧实验研究[J].电子测量与仪器学报,2018,32(6):25-32. 被引量:8
-
4吴春华,黄宵宵,李智华,汪飞.光伏系统直流微弱电弧信号检测研究[J].中国电机工程学报,2019,39(20):6025-6033. 被引量:29
-
5余琼芳,胡亚倩,杨艺.低压交流串联故障电弧检测概述[J].电器与能效管理技术,2020,0(1):24-30. 被引量:22
-
6曾珂,邢丽冬,高杨,王莉.变频系统中交流电弧故障特性及检测技术[J].南京航空航天大学学报,2020,52(2):215-223. 被引量:8
-
7黄宵宵,吴春华,李智华,汪飞.光伏系统直流电弧故障检测方法对比研究[J].太阳能学报,2020,41(8):204-214. 被引量:15
-
8杨卓,蔡晓斌,吴波,谭向宇,唐立军,张文斌.基于近场测量的串联故障电弧传感器[J].传感器与微系统,2022,41(5):99-101. 被引量:3
-
9王尧,田明,谢振华,班云升,侯林明,李奎.基于电流相似度与高频能量的串联故障电弧检测方法[J].电测与仪表,2022,59(6):158-165. 被引量:14
-
10舒奇航,刘希喆,王阳,李丹,张佳云.基于时域波形的交流故障电弧检测[J].电气自动化,2023,45(3):15-16. 被引量:1
-
1蔡彬,陈德桂,吴锐,王鑫伟,高冬梅,陈卫国.开关柜内部故障电弧的在线检测和保护装置[J].电工技术学报,2005,20(10):83-87. 被引量:80
-
2林承志,苏金州,张学军,谢宏灵.低压成套开关设备内部故障电弧研究[J].电工电气,2016(11):44-46. 被引量:3
-
3肖代波,周仿荣,程志万.开关柜内部故障电弧产生的原因[J].云南电力技术,2016,44(A01):110-111.
-
4陈威,熊泰昌.开关柜内部故障电弧的试验研究与特性分析[J].电气时代,2013(8):74-75. 被引量:2
-
5鲁加明,曹伟伟,周振华.550kV GIL母线的结构设计[J].电气技术,2015,16(9):59-63. 被引量:13
-
6宫瑞磊,肖凌风.内部故障电弧下GIS母线壳体的分析及设计[J].高压电器,2013,49(1):118-121. 被引量:11
-
7王娜,刘吉成,张浩.特高压1100kV GIS用母线的研制[J].电力建设,2014,35(6):102-105. 被引量:7
-
8王利,李剑辉,汪世明.中压金属封闭开关设备内部故障电弧的预防和排除[J].电气制造,2007(3):76-79. 被引量:3
-
9梁晓贺,张克选.SF_6气体绝缘金属封闭开关设备壳体耐受内部故障电弧的探讨[J].华通技术,2003,22(4):21-23. 被引量:3
-
10李玲,刘成学.中压开关柜内部故障电弧计算及防护措施[J].高压电器,2014,50(9):131-138. 被引量:22