摘要 制备了具有工业应用价值的V2O5/TiO2负载WO3与MoO3的蜂窝状SCR催化剂,并在某燃煤电厂烟气环境下,对其催化性能进行了测试,结果表明:增大催化剂体积能够提高脱硝效率,但活性增量逐步下降,当脱硝效率达到80%以上时,继续增大催化剂体积其活性提高不显著。催化剂的脱硝活性随着积灰时间的延长而降低,脱硝系统运行4h后,催化剂脱硝活性减少9.4%。在燃煤电厂尾气飞灰浓度约为0.031kg.m-3环境下,为满足尾气中NOx浓度排放要求(<200mg·m-3),每连续运行6h需进行一次吹灰。催化剂的脱硝性能随着运行时间的延长,先急剧下降,后缓慢降低。在连续运行48~168h范围内,脱硝活性下降值小于1%,SO2氧化率下降值小于0.1%。在12个月内,平均每连续运行700h,脱硝活性降低1%。 A honeycomb SCR catalyst of V2O5/TiO2 with WO3 and MoO3 was prepared and its deNOx performance was investigated in a pilot plant test using flue gas of a coal-fired power plant.The results show that the larger catalyst volume is,the higher deNOx efficiency,and SO2 oxidation increases too,but increase ratio becomes smaller.When deNOx efficiency is above 80%,the outlet NOx concentration met the emission standards,and the efficiency improvement is not significant by further enlarging catalyst volume which led to higher construct cost.In order to obtain the best ratio of deNOx efficiency to catalyst volume and avoid resources waste for single requirement of higher deNOx efficiency,SCR catalyst volume should be adjusted for different boiler types,according to flue gas component of coal-fired power plant and national emission standards.The deNOx efficiency reduces with soot increase deposited,and drops about 9.4% within 4 h of soot depositing.The outlet NOx concentration can be at 198 mg·m-3 after 8 h of soot depositing.At 0.031 kg·m-3 of fly ash concentration,the soot deposited needed to be blown each 6 h to obtain a satisfied deNOx efficiency(80%).When run time prolongs,the deNOx efficiency falls sharply first,and then reaches a relative stable level.Within 48—168 h,the deNOx efficiency and SO2 oxidation decline less than 1% and 0.1%,respectively.After continuous run for 3 months(2160 h),the NOx concentration at outlet of SCR tower is 196 mg·m-3.The deNOx efficiency declines at a rate of 1% per 700 h for continuous 12 month run.
出处 《化工学报》 EI CAS CSCD 北大核心 2013年第7期2611-2618,共8页 CIESC Journal
基金 山东省科技发展计划项目(2011GSF11716)~~
关键词 SCR NOx SO2 NH3 燃煤电厂 SCR NOx SO2 NH3 coal-fired power plant
  • 相关文献

参考文献16

  • 1Alemany L J, Berti F, Busca G, et al. Characterization and composition of commercial V2O5-WO3-TiO2 SCR catalysts [ J ]. Applied Catalysis B: Environmental, 1996, 10 (4): 299-311.
  • 2Kim M H, An T H. A commercial V2O5-WO3/TiO2 catalyst used at an NH3-SCR deNOx process in an oil-fired power plant: cause of an increase in deNOxing and NH3 oxidation performances at low temperatures//13th Korean- Japan Symposium on Catalysis [C]. Springer, 2011.
  • 3Xu H, Yan Z Y, Xu X, et al. Experiment study of the pilot ammonia SCR system in a coal-fired power plant//2011 Asia-Pacific Power and Energy Engineering Conference [C]. IEEE, 2011.
  • 4Khodayari R, Odenbrand C U I. Regeneration of commercial TiO2-VzOs-WO3 SCR catalysts used in biofuel plants [J]. Applied Catalysis B : Environmental, 2001, 30 (1/2): 87-99.
  • 5Chen J P, Yang R T. Mechanism of poisoning of the V2O5/ TiO2 catalyst for the reduction of NO by NH3 [J]. Journal of Catalysis, 1990, 125 (2): 411-420.
  • 6Alemany L J, Lietti L, Ferlazzo N, et al. Reactivity and physicochemical characterization of V2O5-WO3/TiO2 de- NOx catalysts [J]. Journal of Catalysis, 1995, 155 (1): 117-130.
  • 7黄海凤,张峰,卢晗锋,陈银飞.制备方法对低温NH_3-SCR脱硝催化剂MnO_x/TiO_2结构与性能的影响[J].化工学报,2010,61(1):80-85. 被引量:39
  • 8吴碧君,肖萍,刘晓勤.MnO_x-WO_3/TiO_2NH_3选择性还原NO_x的催化性能与动力学[J].化工学报,2011,62(4):940-946. 被引量:5
  • 9党帅,钟北京,袁振.130t煤粉炉内煤制气还原NOx的反应机理与CFD耦合计算[J].化工学报,2012,63(8):2544-2550. 被引量:6
  • 10杨娟,汪印,余剑,许光文.活性炭负载金属氧化物常温脱除低浓度NO[J].化工学报,2012,63(8):2538-2543. 被引量:6

二级参考文献64

共引文献94

同被引文献435

引证文献49

二级引证文献250

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部