期刊文献+

穿刺活检联合流式细胞仪检测对恶性淋巴瘤诊断和分型临床研究 被引量:1

Joint flow cytometry biopsy diagnosis of malignant lymphoma and sub clinical research
暂未订购
导出
摘要 目的探讨穿刺活检联合流式细胞仪检测对恶性淋巴瘤诊断和分型的情况。方法回顾性分析2009年3月~2012年3月在我市两所医院就诊的恶性淋巴瘤患者62例,均进行流式细胞仪检测和穿刺活检。结果应用流式细胞仪检测结果为:骨髓受累者55例,其中非霍奇金淋巴瘤45例,霍奇金淋巴瘤10例;应用穿刺活检检测结果为:骨髓受累者28例,其中6例在流式细胞仪检测中未检测出;具有统计学差异(P<0.05)。结论应用流式细胞仪检测比应用穿刺活检法有更高的准确度,但也有假阴性的现象,所以应该将穿刺活检联合流式细胞仪进行检测,这样能提高准确度。 Objective To research alignant lymphoma with the combination of needle biopsy and flow cytometry. Methods Retrospective analysis of 62 cases of malignant lymphoma patients attending two hospitals, from March 2009 to March 2012. Results The results of flow cytometry was that, 55 cases of bone marrow involvement, 45 cases of non-Hodgkin's lymphoma, 10 cases of Hodgkin's lymphoma. The results of needle biopay was that, 28 cases of bone marrow involvement. And 6 cases were not detected by flow cytometry. The 2 sets of results were statistically different. Conclusion Through our research, flow cytometry has higher accuracy than needle biopsy. So the combination of flow cytometry and needle biopsy has higher accuracy.
出处 《中国现代医生》 2013年第18期106-107,共2页 China Modern Doctor
关键词 穿刺活检 流式细胞仪检测 联合检测 Needle biopsy Flow cytometry Joint detection
  • 相关文献

参考文献5

二级参考文献26

  • 1Liberman L, Bracero N, Vuolo MA, et al. Percutaneous large-core biopsy of papillary breast lesions. AJR Am J Roentgenol, 1999, 172:331-337.
  • 2Burbank F. Mammographic findings after 14-guage automated needle and 14-guage directional, vacuum-assisted stereotactic breast biopsies. Radiology,1997,204:153-156.
  • 3Harris GC,Denley HE, Pinder SE, et al. Correlation of histologic prognostic factors in core biopsies and therapeutic excisions of invasive breast carcinoma. Am J Surg Pathol, 2003, 27:11-15.
  • 4Liberman L, Bonaccio E, Hamele-Bena D, et al. Benign and malignant phyllodes tumors: mammographic and sonographic findings. Radiology, 1996, 198:121-124.
  • 5Philpotts LE, Shaheen NA, Carter D, et al. Comparition of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun. AJR Am J Roentgenol, 1999, 172:683-687.
  • 6Berg WA, Krebs TL, Campassi C, et al. Evaluation of 14-and 11- gauge directional, vacuum-assisted biopsy probes and 14-guage biopsy guns in a breast parenchymal model. Radiology, 1997,205:203-208.
  • 7Sneige N,Lim SC,Whitman GJ,et al. Atypical ductal hyperplasia diagnosis by directional vacuum-assisted stereotactic biopsy of breast microcalcifications. Considerations for surgical excision. Am J Clin Pathol, 2003,119,248-253.
  • 8Knight R, Horiuchik K, Parker SH, et al. Risk of needle-track seeding after diagnostic image-guided core needle biopsy in breast cancer. JSLS, 2002, 6:207-209.
  • 9Chao C, Torosian MH, Boraas MC, et al. Local recurrence of breast cancer in the stereotactic core needle biopsy site: case reports and review of the literature. Breast J, 2001, 7:124-127.
  • 10Jackman RJ, Nowels KW, Rodriguze-Soto J, et al. Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up. Radiology, 1999,210:799-805.