期刊文献+

Validation of polymer-based nano-iron oxide in further phosphorus removal from bioeffluent: laboratory and scaled- up study 被引量:2

Validation of polymer-based nano-iron oxide in further phosphorus removal from bioeffluent: laboratory and scaled- up study
原文传递
导出
摘要 The efficient removal of phosphorous from water is an important but challenging task. In this study, we validated the applicability of a new commercially available nanocomposite adsorbent, i.e., a polymer-based hydrated ferric oxide nanocomposite (HFO-201), for the further removal of phosphorous from the bioefftuent discharged from a municipal wastewater treatment plant, and the operating parameters such as the flow rate, temperature and composition of the regenerants were optimized. Labora- tory-scale results indicate that phosphorous in real bioeffluent can be effectively removed from 0.92 mg· L^-1 to 〈 0.5 mg· L^-1 (or even 〈 0.1 mg·L^-1 as desired) by the new adsorbent at a flow rate of 50 bed volume (BV) per hour and treatable volume of 3500-4000BV per run. Phosphorous removal is independent of the ambient temperature in the range of 15℃-40℃. Moreover, the exhausted HFO-201 can be regenerated by a 2% NaOH + 5% NaC1 binary solution for repeated use without significant capacity loss. A scaled-up study further indicated that even though the initial total phosphorus (TP) was as high as 2 mg·L^-1, it could be reduced to 〈 0.5 mg·L^-1, with a working capacity of 4.4-4.8 g·L^-1 HFO- 201. In general, HFO-201 adsorption is a choice method for the efficient removal of phosphate from biotreated waste effluent. The efficient removal of phosphorous from water is an important but challenging task. In this study, we validated the applicability of a new commercially available nanocomposite adsorbent, i.e., a polymer-based hydrated ferric oxide nanocomposite (HFO-201), for the further removal of phosphorous from the bioefftuent discharged from a municipal wastewater treatment plant, and the operating parameters such as the flow rate, temperature and composition of the regenerants were optimized. Labora- tory-scale results indicate that phosphorous in real bioeffluent can be effectively removed from 0.92 mg· L^-1 to 〈 0.5 mg· L^-1 (or even 〈 0.1 mg·L^-1 as desired) by the new adsorbent at a flow rate of 50 bed volume (BV) per hour and treatable volume of 3500-4000BV per run. Phosphorous removal is independent of the ambient temperature in the range of 15℃-40℃. Moreover, the exhausted HFO-201 can be regenerated by a 2% NaOH + 5% NaC1 binary solution for repeated use without significant capacity loss. A scaled-up study further indicated that even though the initial total phosphorus (TP) was as high as 2 mg·L^-1, it could be reduced to 〈 0.5 mg·L^-1, with a working capacity of 4.4-4.8 g·L^-1 HFO- 201. In general, HFO-201 adsorption is a choice method for the efficient removal of phosphate from biotreated waste effluent.
出处 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2013年第3期435-441,共7页 环境科学与工程前沿(英文)
关键词 bioeffluent phosphorus removal nanocom-posite adsorbent hydrated ferric oxide bioeffluent, phosphorus removal, nanocom-posite adsorbent, hydrated ferric oxide
  • 相关文献

参考文献5

二级参考文献80

共引文献214

同被引文献17

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部