期刊文献+

电网频率下降时CPR1000反应堆主泵和电机瞬态分析 被引量:4

Transient Analysis for CPR1000 Reactor Main Pump and Electromotor
在线阅读 下载PDF
导出
摘要 本文根据电机学原理,用RETRAN-02程序模拟电网频率下降时电动机的运行特性。同时模拟了CPR1000主冷却剂泵的水力特性和反应堆冷却剂系统的阻力特性。完整地研究主冷却剂泵和电机在电网频率下降时的运行瞬态。最后分析电网频率以4 Hz/s下降时CPR1000主冷却剂泵和电机的瞬态行为。 The operation characteristics of electromotor are simulated with RETRAN-02 when the electric network frequency falls based on the electro mechanics principle. The hydraulics characteristics of CPR1000 reactor main coolant pump and the resistance characteristics of the reactor coolant system are also simulated. The operation transient of the reactor coolant pump and electromotor is studied in detail when the electric network frequency falls. In the end, the transient behavior of CPR1000 reactor coolant pump and electromotor is analyzed when the electric network frequency falls at the rate of 4 Hz/s.
作者 肖三平
出处 《核动力工程》 EI CAS CSCD 北大核心 2013年第3期152-155,共4页 Nuclear Power Engineering
关键词 反应堆冷却剂主泵 电机 转差率 电磁转矩 电网频率 Reactor main coolant pump, Electromotor, Revolutional slip, Magnetic torque, Electric network frequency
  • 相关文献

参考文献2

  • 1RCC.E.法国压水堆核电站建造标准,核岛电气设备设计和建造规则[s].2002.
  • 2汤蕴璎,罗应立,梁艳萍.电机学[M].北京:机械工业出版卒土,2008.