期刊文献+

SAFIRE/FBP算法冠状动脉CTA图像质量的对比研究 被引量:4

The comparative study on image quality of coronary computed tomography angiography by iterative reconstructions and filtered back projection
暂未订购
导出
摘要 目的探讨新一代迭代重建算法(SAFIRE)与滤波反投影(FBP)算法在冠状动脉CT血管造影(CCTA)图像质量上的差异。方法回顾性收集分析80例行双源CT(DSCT)冠状动脉CCTA检查的患者,记录患者身高、体质量、性别、心率,将80例行双源CT检查患者的冠脉原始图像,在工作站上分别进行FBP(A组)及SAFIRE(B组)两种算法的图像重建,应用秩和检验对两组图像的主观评分进行比较,应用t检验对两组图像的客观指标进行比较。结果 (1)A组可评价的冠脉数约972条,B组可评价的冠脉数约984条;A组主观图像质量评分约(3.66±0.26);B组约为(3.70±0.25),两组间比较差异无统计学意义(P=0.113);A组评分为优的冠状动脉(787/972)高于B组评分为优的冠状动脉(866/984),P=0.000。(2)A与B两组图像信噪比(SNR)、对比噪声比(CNR)及图像噪声指数(SD值)比较差异有统计学意义(P<0.05)。A与B组冠状动脉平均CT值分别为(448.63±77.00)HU,(444.82±77.91)HU,P=0.756。结论新一代迭代重建算法(SAFIRE)在相同扫描条件下可以提高图像质量。 Objective The purpose of this study was to investigate the image quality and image noise in second-generation coronary computed tomography angiography(CCTA)with iterative reconstructions which based on the original data.Methods Between March 2012and April 2012,we enrolled 80patients with CCTA.For the CCTA scan(SOMATOM Definition Flash,Siemens),data sets were reconstructed with Sinogram Affirmed Iterative Reconstruction(SAFIRE,Siemens)and filtered back projection(FBP).We aslo recorded height,weight,gender and heart rate.Mann-Whitney-U-test and t-test were used for statistical analysis.Results There was no significant statistic difference for the scoring of subjective image assessment.However,the quantity of high mark with A was higher than B.The mean SNR and CNR were significantly lower with protocol A than B(P0.01).the mean image noise was significantly higher with protocol A than B(P0.01).the coronary attenuation were not significantly statistically.Conclusion Compared with standard FBP reconstruction,SAFIRE improves image quality and has the potentialto decrease radiation dose.
出处 《重庆医学》 CAS CSCD 北大核心 2013年第17期1952-1954,共3页 Chongqing medicine
基金 重庆市卫生局科研基金资助项目(10-2-05)
关键词 体层摄影术 X线计算机 冠状血管 图像质量 迭代重建 tomography X-ray computed coronary vessels image quality iterative reconstruction
  • 相关文献

参考文献14

  • 1Bulla S,Pache G,Langera M,et al.Reducing the radiationdose for low-dose CT of the paranasal sinuses using itera-tive reconstruction:feasibility and image quality[J].Eur JRadiol,2011,5(10):5541-5543.
  • 2亓恒涛,王敏,秦维昌,柳澄.双源CT与64层螺旋CT冠状动脉图像质量及辐射剂量的研究[J].中华放射医学与防护杂志,2010,30(1):87-88. 被引量:3
  • 3Lee SJ,Park SH,Kim AY,et al.A prospective compari-son of standard-dose CT enterography and 50% reduced-dose CT enterography with and without noise reductionfor evaluating crohn disease[J].AJR Am J Roentgenol,2011,197(1):50-57.
  • 4Renker M,Ramachandra A,Schoepf UJ,et al.Iterativeimage reconstruction techniques:applications for cardiacCT[J].J Cardiovasc Comput Tomogr,2011,5(4):225-230.
  • 5Hu XH,Ding XF,Wu RZ,et al.Radiation dose of non-en-hanced chest CT can be reduced 40 % by using iterativereconstruction in image space [J].Clin Radiol,2011,66(11):1023-1029.
  • 6May MS,Wiist W,Brand M,et al.Dose reduction in ab-dominal computed tomography:intraindividual comparisonof image quality of full-dose standard and half-dose itera-tive reconstructions with dual-source computed tomo-graphy[J].Invest Radiol?2011,46(7):465-470.
  • 7Achenbach S,Goroll T, Seltmann M,et al.Detection ofcoronary artery stenoses by low-dose,prospectively ECG-triggered,high-pitch spiral coronary CT angiography[J].J ACC Cardiovasc Imaging,2011,4(4):328-330.
  • 8Moscariello A,Richard AP,Takx U,et al.Coronary CTangiography:image quality,diagnostic accuracy,and po-tential for radiation dose reduction using a novel iterativeimage reconstruction technique-comparison with tradition-al filtered back projection [J],Eur Radiol,2011,21(10):2130-2138.
  • 9Maffei E,Martini C,Rossi A,et al.Diagnostic accuracy ofsecond-generation dual-source computed tomography cor-onary angiography with iterative reconstructions:a real-world experience[J].Radiol Med,2011,17(1):36-40.
  • 10Saebeom H,Jeong Min L,Soo JK’et al.80-kVp CT usingiterative reconstruction in image space algorithm for thedetection of hypervascular hepatocellular carcinoma:phantom and initial clinical experience[J].Korean J Radi-ol,2012,13(2):152-164.

二级参考文献5

  • 1Flohr TG, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image reconstruction techniques. Radiology, 2005,235 (3) :756-773.
  • 2Flohr T, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006,16 (2) :256-268.
  • 3Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation, 1975,51 ( 1 ) :5-40.
  • 4Menzel HG, Schibilla H, Teunen D, et al. European guidelines on quality criteria for computed tomography. Luxembourg: European Commission, 2000.
  • 5McCollough C, Primak A, Saba O, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology, 2007,243 (3) : 775-784.

共引文献2

同被引文献28

  • 1James PT. Obesity: The worldwide epidemic[J]. Clin Dermatol, 2004,22(4) :276-280.
  • 2Hur G, Hong SW, Kim SY,et al. Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography[J].AJR Am J Roentgenol, 2007,189 (1) : 188-196.
  • 3Sehoenhagen P, Halliburton SS, Stillman AE, et al.Noninvasive imaging of coronaryarteries: current and future role of multi- detector row CT[J].Radiology,2004,232(1) :7-17.
  • 4Nelson RC, Feuuuerlein S, Boll DT, et al. New iterative reconstruction techniques for cardiovascular commmputed tomography:How do they work, and what are the advantages and disadvantages and disadvantages[J]. J Cardiovase Comput Tomogr, 2011,5(5): 286-292.
  • 5Alkadhi H, Stolzmann P, Scheffel H, et al. Radiation dose of cardiac dual-source CT.The cffect of tailoring the protocol to patient-specific parameters[J]. Eur J Radio1,2008,68 ( 3 ) 385-391.
  • 6Leschka S,Stinn B,Schmid F, et al.Dual source CT coronary angiography in severely obese patients: Trading off temporal resolution and image noise[J]. Invest Radiol, 2009,44 ( 11 ) : 720-727.
  • 7Chinnaiyan KM, Mc Cu Uough PA, Flohr TG, et al.Improved noninvasive coronary angiography in morbidly obese patients using dual source computed tomography and half-scan reeonstruction[J]. J Cardiovasc Comput Tomogr, 2009, 3 (1): 35-42.
  • 8Moscariello A,Takx RA,Schoepfu J ,et al.coronary CT angiography: Image quallty, diagnostic accuracy, and potentiaI for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back proiection[J].Eur Radiol,2011,21(10) :2130-2138.
  • 9田锦林,杜亚辉,王伟,李云松,李春雷,陈硕飞.选择性肾动脉栓塞治疗急性肾挫裂伤出血[J].中国介入影像与治疗学,2010,7(6):609-612. 被引量:15
  • 10王瑞,张兆琪,郭淼,黄晓勇,于薇,王永梅,晏子旭,毕涛,于洋,池立群.双能量CT冠状动脉成像结合CT心肌灌注诊断冠心病准确性的初步研究[J].中华放射学杂志,2011,45(2):111-115. 被引量:44

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;