期刊文献+

非平衡等离子体微型消毒器模型的性能研究 被引量:3

STUDY ON MINIATURE STERILIZER MODEL BASED ON NON-EQUILIBRIUM PLASMA
原文传递
导出
摘要 目的研制非平衡等离子体微型消毒器模型并观察其杀菌效果。方法采用载体定量杀菌试验方法和电镜观察法,对非平衡等离子体微型消毒器模型杀菌效果进行实验室观察。主要部件涉及变压器、陶瓷电极和分散器等;根据物品表面消毒的实际需要,以细菌繁殖体为试验菌,用载体法进行杀菌试验,根据活菌计数和电镜观察法初步鉴定消毒器模型消毒效果。结果微型消毒器模型发射的等离子体为紫蓝色气体状物质。经该微型消毒器产生的平均温度约40℃等离子体处理20s后,对纸片上金黄色葡萄球菌、大肠杆菌和白色念珠菌的杀灭率均达到100%。作用后标本经透射电镜观察到细菌形态变异,菌体结构受到明显破坏。结论非平衡等离子体微型消毒器可产生温度低、具有良好杀菌作用的等离子体,达到设计目标。 Objective To study a miniature sterilizer model based on non - equilibrium plasma and its germicidal effect. Methods Quantitative carrier germicidal test and electron microscope was adopted to observe the germicidal ecacy of the miniature sterilizer model based on non -equilibrium plasma which mainly includes transformer, ceramic electrode and dis- perser, etc. ; based on the actual needs of surface disinfection, carrier method is used to observe the disinfection effect by bacteria counts and electron microscope. Results Plasma generated by miniature sterilizer model is purple blue gas. The killing rate of Staphylococcus aureus, Escherichia coli and Candida albicans are all 100% after exposed to the plasma gas a- bout 40℃ for 20 s. And the bacteria morphology and structural all changed. Conclusion The miniature sterilizer model generates plasma of low temperature, has good germicidal effect and reaches our design purpose.
机构地区 第三军医大学
出处 《中国消毒学杂志》 CAS 北大核心 2013年第5期405-408,共4页 Chinese Journal of Disinfection
基金 重庆市科技攻关计划项目(编号:cstc2012gg-yyjs10020) 重庆市医学科研计划项目(编号:2012-1-081)
关键词 非平衡等离子体 微型消毒器 杀菌效果 电镜观察 non - equilibrium plasma miniature sterilizer germicidal efftcacy electron microscope observation
  • 相关文献

参考文献12

  • 1朱世尧.等离子体物理基础[M].北京:科学出版社,1983.9.
  • 2石兴民,张冠军,袁育康,马跃,许桂敏,顾宁.低温等离子体对细菌芽孢的灭活研究[J].南方医科大学学报,2009,29(10):2033-2036. 被引量:9
  • 3Cotter JJ,Maguire P,Soberon F,et al.Disinfection of meticillin-resistant Staphylococcus aureus and Staphylococcus epidermidisbiofilms using a remote non-thermal gas plasma[J].J Hosp In-fect,2011,78(2):204.
  • 4林晨,张晶,沈伟哉,岑颖洲,江振友.枸骨叶不同溶媒萃取物对二种念珠菌作用的研究[J].中国人兽共患病杂志,2005,21(9):821-822. 被引量:6
  • 5Brun P,Vono M,Venier P,et al.Disinfection of ocular cells andtissues by atmospheric-pressure cold plasma[J].PLoS One,2012,7:e33245.
  • 6蒋景华.过氧化氢低温等离子体灭菌器灭菌效果监测[J].中国消毒学杂志,2010,27(6):769-770. 被引量:5
  • 7Perni S,Shama G,Kong MG.Cold atmospheric plasma disinfec-tion of cut fruit surfaces contaminated with migrating microorgan-isms[J].J Food Prot,2008,71(8):1619.
  • 8Noriega E,Shama G,Laca A,et al.Cold atmospheric gas plas-ma disinfection of chicken meat and chicken skin contaminatedwith Listeria innocua[J].Food Microbiol,2011,28((7):1293.
  • 9Jacobs P,R Kowatsch.Sterrad Sterilization System:a new tech-nology for instrument sterilization[J].Endosc Surg Allied Techn-ol,1993,1(1):57.
  • 10顾春英,薛广波.等离子体消毒和灭菌[J].上海预防医学,1999,11(11):486-491. 被引量:18

二级参考文献14

  • 1吴旭琴,王守国,韩黎,赵玲利,常啸,陈耕,索继江,邢玉斌,陈世平.常压低温等离子体对微生物的杀灭研究[J].微生物学报,2005,45(2):312-314. 被引量:23
  • 2石兴民,袁育康,孙岩洲,袁网,彭风玲,邱毓昌.Experimental Research of Inactivation Effect of Low-Temperature Plasma on Bacteria[J].Plasma Science and Technology,2006,8(5):569-572. 被引量:10
  • 3陆德源.医学微生物学(第五版)[M].北京:人民卫生出版社,1999.补页码.
  • 4.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 5National Committee for Clinical Laboratory Standards. Reference method for broth dilution antifungal sesceptibility testing of yeast Tentative standard M27 -T[M]. Pennsylvania: NCCLS, 1995:1 -22.
  • 6Haraguehi H, kataoka S, Okamoto S, et al. Antimicrobial triterpenes from Ilex integra and the mechanism of antifungal action [J] . Phytother Res, 1999, 13(2): 151 - 156.
  • 7Gadri RB,Roth JR,Montie TC,et al.Sterilization and plasma processing of room temperature surfaces with a one atmosphere uniform glow discharge plasma(OAUGDP)[J].Surface and Coatings Technology,2000; 131:528
  • 8Roth JR,Tsai P,Liu C,et al.One atmosphere uniform glow discharge plasma[P].U.S.Patent 5414324 1995.
  • 9Laroussi M.N.Decontamination of Biological Media by Atmospheric-Pressure Plasmas:Review,Analysis,and Prospects[J].IEEE TRANS PLASMA SCI,2002; 30(4):1409.
  • 10K Kelly-Wintenberg,T C Montie,C Brickman,J R Roth,A K Carr,K Sorge,L C Wadsworth,P P Y Tsai. Room temperature sterilization of surfaces and fabrics with a One Atmosphere Uniform Glow Discharge Plasma[J] 1998,Journal of Industrial Microbiology & Biotechnology(1):69~74

共引文献50

同被引文献19

  • 1姜玉,秦克勤,张善端,朱绍龙,张源,邓续周,宋伟民.大气压辉光放电等离子体对不同细菌杀灭效果的研究[J].中国消毒学杂志,2007,24(1):1-3. 被引量:12
  • 2姜玉,秦克勤,张善端,宋伟民.大气压辉光放电等离子体消毒效果影响因素[J].中国消毒学杂志,2007,24(2):109-111. 被引量:6
  • 3.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 4GALVIN S,CAHILL O,O'CONNOR N,et al. The antimicrobialeffects of helium and helium-air plasma on Staphylococcus aureusand Clostridium difficile[J].Lett Appl Microbiol,2013,57(2):83-90.
  • 5CAHILL O J,CLARO T,O'CONNOR N,et al. Cold air plasma todecontaminate inanimate surfaces of the hospital environment[J].Appl Environ Microbiol,2014,80(6):2004-2010.
  • 6KOSTOV K G,ROCHA V,KOGA-ITO C Y,et al. Bacterial sterilizationby a dielectric barrier discharge (DBD) in air[J].Surf CoatTechnol,2010,204:2954-2959.
  • 7VASSAL S,FAVENNEC L,BALLET J J,et al. Hydrogen peroxidegas plasma sterilization is effective against Cryptosporidium parvumoocysts[J].Am J Infect Control,1998,26(2):136-138.
  • 8SELCUK M,OKSUZ L,BASARAN P. Decontamination of grainsand legumes infected with Aspergillus spp. and Penicillum spp. bycold plasma treatment[J].Bioresource Technol,2008,99(11):5104-5109.
  • 9Noriega E,Shama G,Laca A,et al.Cold atmospheric gas plasma disinfection of chicken meat and chicken skin contaminated with Listeria innocua[J].Food Microbiol,2011,28(7):1293-1300.
  • 10Brun P,Vono M,Venier P,et al.Disinfection of ocular cells and tissues by atmospheric-pressure cold plasma[J].Plos One,2012,(7):e33245.

引证文献3