摘要 螺栓连接的组合角钢是输电线路工程常用的结构形式,需要计算的内容有:组合断面绕虚轴的整体稳定、连接螺栓的剪力、分肢角钢的受压和受弯、双拼十字断面缀板的强度。然而现行规范GB50017—2003《钢结构设计规范》未给出计算公式,其中给出的填板间距更适合焊接或铆接的组合断面。欧洲钢结构规范对于连接螺栓的剪力也未给出计算公式。由于普通螺栓连接的滑动引起承载力降低,对绕虚轴剪切变形较小的组合角钢,可以不考虑填板厚度引起的虚轴回转半径增大;而对绕虚轴剪切变形较大的双拼十字组合角钢,按格构式轴心受压缀板组合构件的原理,对换算长细比加以修正放大,计算整体稳定;根据挠曲变形,给出连接螺栓的剪力和分肢角钢承载力的计算公式。 Combined angle steel connected with bolts is a common structure in power transmission line project, the calculation contents of which include: the overall stability of combination section around virtual axis, the connecting bolt shear, buckling and bending of component angle, strength of battens on star-battened angle member. However, the current code GB 50017--2003 ("Code for design of steel structures") has not given the calculation formula, in which the battens distance is more suitable for welded or riveted combination section. The steel structure code in Europe also has not given the calculation formula of connecting bolt shear. Aimed to the decrease of bearing capacity caused by the sliding of ordinary bolt connection, and the small shear deformation of combined angle steel on the empty axis, the pads thickness caused by the increases of virtual axis' gyration radius can be not considered. But for the star-battened combined angle steel around virtual axis with large shear deformation, the equivalent slenderness ratio should be corrected and amplified to calculate its overall stability, according to the combination principle of battened member with lattice type axis compression; the calculate formulas of connecting bolt's shear and component angle's bearing capacity are proposed, according to the flexural deformation.
出处 《电力建设》 2013年第5期80-85,共6页 Electric Power Construction
关键词 组合角钢 换算长细比 分肢角钢 分肢长细比 剪力 combined angle steel equivalent slenderness ratio component angle component slenderness ratio shear
  • 相关文献

参考文献10

  • 1GB50017-2003.钢结构设计规范[S].[S].,..
  • 2DL/T5151-2002架空输电线路杆塔结构设计技术规定[S].
  • 3EN 1993 - 1 - 1 : 2005 ( E), Eurocode3 : Design of steel structures- Part 1 - 1 : General rules and rules for buildings[S].
  • 4左元龙,赵峥,付鹏程,王贵年.大跨越输电铁塔十字组合角钢填板的设计与试验[J].武汉大学学报(工学版),2007,40(S1):209-213. 被引量:18
  • 5孙训方,方孝淑,关来泰.材料力学[M].北京:人民教育出版社,2001.
  • 6中国电力科学研究院.500kV秦山核电送出至海宁变线路工程TJT1转角塔试验报告[R].北京:中国电力科学研究院,2011.
  • 7郭勇,沈建国,应建国.输电塔组合角钢构件稳定性分析[J].钢结构,2012,27(1):11-16. 被引量:23
  • 8杨天样.结构力学[M].北京:人民教育出版社,1979.
  • 9李振宝,石鹿言,刑海军,唐贞云,杨小强.Q420双角钢十字组合截面压杆承载力试验[J].电力建设,2009,30(9):8-11. 被引量:31
  • 10夏志斌,王国周,李继华,等.钢结构设计规范(GBJ17-88)内容讲解及计算示例[R].北京:北京钢铁设计研究总院、钢结构设计规范国家标准管理组,1988.

二级参考文献17

共引文献2110

同被引文献38

引证文献5

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部