期刊文献+

顶空气相色谱法测定空心胶囊中环氧乙烷残留量 被引量:3

Determination of residual ethylene oxide in hollow capsules by the headspace GC
在线阅读 下载PDF
导出
摘要 针对2010年版中国药典规定的顶空气相色谱法测定空心胶囊中环氧乙烷残留量的干扰物问题,使用气相色谱-质谱(GC-MS)联用技术进行了系统的考察,发现干扰物主要来自实验用水中溶解的CO2,对实验用水在使用前加热煮沸即可有效地去除干扰.同时,选用RTX-WAX色谱柱,在柱温40℃,载气流量0.8 mL/min时分离效果和峰型最好.在此基础上对药典方法进行了改进,实验结果表明:环氧乙烷含量为0.21~12.67μg时呈良好的线性关系,相关系数r=0.999 9;最低检出限为0.03μg,加标回收率为98.6%~103.2%,相对标准偏差为0.7%~1.7%. Distractors in the determination of the residual ethylene oxide in hollow capsules by the headspace gas chromatography in the Chinese Pharmacopoeia of 2010 edition was systematically studied by GC-MS.Interference source was examined and found that interfering substances mainly came from CO2 which dissolved in the experiment water and the boiled distilled water interference could be removed.Using RTX-WAX column in the column temperature of 40 ℃ and carrier gas flow 0.8 mL/min the ethylene oxide separated well and the peak pattern was preferably.The results showed that the concentration of ethylene oxide in the range of 0.21-12.67 μg had good linear relationship.The correlation coefficient was 0.999 9.The limit of detection was 0.03 μg/mL.The recoveries ranged from 98.6% to 103.2% and the relative standard deviation was from 0.7% to 1.7%.
出处 《浙江师范大学学报(自然科学版)》 CAS 2013年第2期193-197,共5页 Journal of Zhejiang Normal University:Natural Sciences
基金 国家自然科学基金资助项目(31171748) 山西省特色重点学科基金资助项目 山西省研究生优秀创新项目(20123015)
关键词 空心胶囊 环氧乙烷 干扰物 气相色谱-质谱联用 顶空气相色谱 hollow capsules ethylene oxide distractors GC-MS headspace GC
  • 相关文献

参考文献8

  • 1杨君,王燕萍,王敏荣.顶空气相色谱法检测一次性医疗用品中环氧乙烷残留量[J].中国卫生检验杂志,2010,20(6):1345-1346. 被引量:8
  • 2Thomas R Z, Ruben J L, ten Bosch J J, et al. Effect of ethylene oxide sterilization on enamel and dentin demineralization in vitro [ J ]. J Dent, 2007,35 (7) :547-551.
  • 3Azzam M G, Roy M E, Whiteside L A. Second-generation locking mechanisms and ethylene oxide sterilization reduce tibial insert backside dam- age in total knee arthroplasty[J].J Arthroplasty ,2011,26 (4) :523-530.
  • 4Archer E, Allen H, Hopwood A, et al. Validation of a dual cycle ethylene oxide treatment technique to remove DNA from consumables used in forensic laboratories[ J]. Forensic Sci Int Genet,2010,4(4) :239-243.
  • 5张霞,周雯,王有森.环氧乙烷在灭菌物品中残留量测定及毒性研究进展[J].中国消毒学杂志,2005,22(2):217-218. 被引量:59
  • 6Natarajan A T, Preston R J, Dellarco V, et al. Ethylene oxide:evaluation of genotoxicity data and an exploratory assessment of genetic risk [ J ] Mutat Res, 1995,330(1/2) :55-70.
  • 7Melnick R L, Sills R C. Comparative carcinogenicity of 1,3-butadiene, isoprene, and chloroprene in rats and mice [ J ]. Chem Biol Interact 2001,135/136:27-42.
  • 8张雅青,李平.气相色谱法测定空心胶囊中环氧乙烷残留量[J].江西医药,1987,22(5):459-461.

二级参考文献26

共引文献63

同被引文献25

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史