期刊文献+

超声成像中基于虚拟阵元的双聚焦波束合成方法 被引量:2

The method of dual focusing beamforming based on virtual element in ultrasound imaging
原文传递
导出
摘要 针对传统动态接收聚焦DRF波束合成方法在超声成像中分辨率和探测深度方面存在的不足,提出一种基于虚拟阵元的双聚焦波束合成方法。首先利用单一固定焦点进行第一次聚焦;然后利用虚拟阵元的概念计算第二次聚焦的延时参数;最后再根据延时叠加波束合成的原理及动态聚焦技术进行第二次聚焦,得到最终成像的扫描线数据。为验证该方法的有效性,进行了点散射目标成像实验。实验结果表明:双聚焦波束合成的超声成像方法在一定程度上有效地调和了分辨率与探测深度之间的矛盾,提高了超声成像的质量。 According to the resolution and investigation depth deficiency of traditional dynamic receiving focusing (DRF) beamforming in ultrasound imaging,a dual focusing beamforming method based on virtual element is proposed. Firstly, single fixed focus point is used in the first focusing; and then the delay parameters used in the second focusing are calculated with the concept of virtual element; in the end the second focusing is carried out by delay-and-sum dynamic focus technique to obtain the imaging data. The experiments based on point pattern are used to verify the proposed method. The experimental results indicate that dual focusing beamforming applied to ultrasound imaging can resolve the contradiction between resolution and investigation depth in some extent and the method of dual focusing beamforming can effectively improve the imaging quality.
出处 《重庆大学学报(自然科学版)》 EI CAS CSCD 北大核心 2013年第5期75-79,共5页 Journal of Chongqing University
基金 广东省教育部产学研结合项目(2008B090500272) 重庆市科技攻关项目(2011GGC159)
关键词 波束合成 超声成像 双聚焦 延时叠加 beamforming ultrasonic imaging dual focusing delay-and-sum
  • 相关文献

参考文献13

  • 1王平,许琴,王伟明,何为,陈民铀.超声成像系统的动态孔径控制方法[J].重庆大学学报(自然科学版),2011,34(3):89-93. 被引量:1
  • 2Ye L, Jensen J A. Synthetic aperture flow imaging using a dual stage beamformer approach [C] // Proceedings of the 2010 IEEE Ultrasonics Symposium, October 11-14,2010, San Diego, CA. Piseataway: IEEE Press, 2010 : 1924-1927.
  • 3Frazier C H, O' Brien W D. Synthetic aperture techniques with a virtual source element[J]. IEEE Transactions on Ultrasonics, Ferroelectrics andFrequency Control, 1998,45 (1) : 196-207.
  • 4Passmann C, Ermert H. A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics [J].IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 1996, 43 (4) : 545-552.
  • 5Jacob K. Synthetic aperture sequential beamforming and other beamforming techniques in ultrasound imaging [ D ]. Denmark: Technical University of Denmark,2008.
  • 6Hemmsen M C. Image processing in medical ultrasound[D]. Denmark: Technical University of Denmark, 2011.
  • 7Jensen J A. Users' guide for the field II program[D]. Denmark : Technical University of Denmark, 2011.
  • 8Jensen J A. Field:a program for simulating ultrasound systems [J]. Medical Biological Engineering, 1996, 34(Supl) :351-353.
  • 9Hemmsen M C, Kortbek J, Nikolov S I, et al. Simulation of high quality ultrasound imaging[C]/// Proceedings of the 2010 IEEE Ultrasonics Symposium, October 11-14,2010, San Diego, CA. Piscataway: IEEE Press,2010:1739-1742.
  • 10Hergum T, Langeland S, Remme E W, et al. Fast ultrasound imaging simulation in K-space[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control ,2009,56(6) : 1159-1167.

二级参考文献13

  • 1许雪莹,葛剑敏,刘镇清.线阵换能器阵元宽度对主瓣半功率点宽度的影响[J].声学技术,2005,24(1):61-63. 被引量:7
  • 2唐浩漾,齐长远,赵健,康雪艳,杨汝良.子孔径相关算法研究[J].西北大学学报(自然科学版),2005,35(6):720-722. 被引量:3
  • 3HOI.FORT I'K, GRAN F, JENSEN J A. P2B-12 Minimum variance Beamforming for high frame rate ultrasound imaging [C/OL] // IEEE Ultrasonics Symposium,New York, October 28-31,2007E2007 12 261.http://ieeexplore, ieee. org/search/srchabstract. isp? tp = &.arnumber = 4409961&.queryText% 3DMininmm-variance + Beamforming + for + high + framerate + ultrasound + imaging% 26opened Refinements % 3D *% 26 searchField % 3DSearch + All.
  • 4WAN Y Y, EBBINII E S. Imaging with concave large aperture therapeutic ultrasound arrays using conventional synthetic aperture beamforming[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, Arid Frequency Control, 2008, 55(8): 1705 1718.
  • 5GUENTHER D A, WALKER W F. Optimal apodization design for medical ultrasound using constrained least squares part I: theory[J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2007,54(2):332-342.
  • 6GUENTHER D A, WALKER W F. Optimal apodization design for medical ultrasound using constrained least squares part II: Simulation results [J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2007, 54(2):343-358.
  • 7SYNNEVAG J F, AUSTENG A, HO1.M S. Adaptive beamforming applied to medical ultrasound imaging[J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2007, 54(8) :1606-1613.
  • 8ASL B M, MAHLOOJIFAR A. Minimum variance beamforming combined with adaptive coherence weighting applied to medical uhrasound imaging [J]. IEEE Transactions on Ultrasonics, Ferroelectrics. and Frequency Control, 2009 (9), 56 (9) : 1923-1931.
  • 9DAHERN M, YENJ T. 2 Darrayfor3 Duhrasound imaging using synthetic aperture techniques[J]. IEEE Transactions On Ultrasonics, Ferroelectrics, And Frequency Control, 2006, 53(5): 912 924.
  • 10HERGUM T, LANGELAND S, REMME E W, et al. Fast ultrasound imaging simulation in K-space [J]. IEEE Transactions On Ultrasonics, Ferroelectrics, And Frequency Control, 2009, 56(6): 1159-1167.

同被引文献19

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部