期刊文献+

基于回光强度的地面三维激光扫描仪测距误差模型 被引量:10

Model of terrestrial laser scanner range errors based on intensity of echo
原文传递
导出
摘要 地面三维激光扫描仪是一种新型测量仪器,其核心优势是非接触、速度快、精度高,应用领域非常广泛,而使用之前的设备检校极为重要。影响地面三维激光扫描仪测距精度的因素很多,本文的研究以地面三维激光扫描仪测距原理及误差来源为基础,提出一种稳健的曲线拟合算法对点云数据进行处理,建立了基于回光反射强度的地面三维激光扫描仪测距误差模型,经实验验证取得了良好效果。 Terrestrial Laser Scanner is a new measuring instrument, its core strengths are non-contact, high speed, high preci- sion, and abroad application, so the equipment calibration of TLS is very important. There are many factors that affect the accuracy of TLS, but few studied on the model about range errors of TLS based on the intensity of echo. Based on the principles of TLS and the ranging error sources, the paper proposed a robust curve fitting algorithm to process point cloud data, then built the model of TLS range errors based on the intensity of echo. which could held improve the ranain~ accuracy.
出处 《测绘科学》 CSCD 北大核心 2013年第3期169-171,174,共4页 Science of Surveying and Mapping
基金 国家科技重大专项大型高温锻件热态在位检测技术项目(2009ZX04014-093)
关键词 地面三维激光扫描仪 回光强度 测距误差 误差模型 光衰减器 terrestrial laser scanner intensity of echo range errors error model optical attenuator
  • 相关文献

参考文献5

  • 1杨伟,刘春,刘大杰.激光扫描数据三维坐标转换的精度分析[J].工程勘察,2004,32(3):61-63. 被引量:56
  • 2Jana MAZALOVA Katei'ina, VALENTOVA, Lenka VLCKOVA. Testing of Accuracy of Reflectorless Distance Measurement of Selected Leica and Topcon Total Stations [J]. GeoScience Engineering. 2010, 6: 19-26.
  • 3Staiger R. The geometrical Quality of laser scanner [ EB/OL]//Proceedings of FIG Working Week 2005 and GSDI- 8, Cairo, Egypt2005, April: 16-21, ULR. ( 2005-11 ) . http ://www. fig. net/pub/cario/index, htm.
  • 4Yuriy Reshetyuk. Investigation and calibration of pulsed time-of-flight, TLS [ I) ]. Stockholm: Royal Institute of Technology,2006.
  • 5陈千颂,杨成伟,潘志文,霍玉晶.激光飞行时间测距关键技术进展[J].激光与红外,2002,32(1):7-10. 被引量:59

二级参考文献22

  • 1刘大杰.全球定位系统(GPS)的原理与数据处理[M].上海:同济大学出版社,1997.163-166.
  • 2K Maatta,J Kostamovaara. A high-precision time-to-digital converter for pulsed time-to-flight laser radar applications[J].IEEE Trans.Instr.and Meas.,1998.47(2):521-536.
  • 3T Araki.Optical distance meter using a short pulse width laser diode and a fast avalanche photodiode[J].Rev.Sci.Instrum.,1995,66(1):43-47.
  • 4P Palojrvi,T Ruotsalainen,J Kostamovaara.A new approach to avoid walk error in pulsed laser rangefinding [J].IEEE Intern.Sympos.on Circu.and Systems Pro.1999,I-258-I-261.
  • 5W A Kielek.Random error in timing using weak light pulse,photomultiplier,and threshold crossing detection [J].IEEE Trans.Inst.And Meas.,1998,47(2):543-550.
  • 6M L Simpson,M J Paulus.Discriminator design considerations for time-interval measurement circuits in collider detector systems [J].IEEE Trans.Nucl.Sci.,1998,45(1):98-104.
  • 7T Araki,S Yokoyama,N Suzuki.Simple optical distance meter using an intermode-beat modulation of a He-Ne laser and an electrical-heterodyne technique [J].Rev.of Sci.Instru.,1994,65(6):1883-1888.
  • 8K Seta,T O'ishi.distance meter utilizing the intermode beat of a He-Ne laser [J].App.Opt.,1990,29(3):354-359.
  • 9K Seta,T Oh'ishi.Distance measurement using a pulse train emitted from a laser diode[J].J.App.Phy.,1987,26(10):L1690-L1692.
  • 10M Lescure,T Bosch,A Dziadowiec.An electro-optical frequency doubling method to remove electrical noise in laser rangefinders[J].IEEE Trans.on Instru.and Meas.,1991,IM-40(60):1046-1047.