期刊文献+

对北京地区利用冷却塔进行冬季空调制冷的分析

Analysis of Winter Air-Conditioning Refrigeration Using Cooling Tower in Beijing Area
在线阅读 下载PDF
导出
摘要 冷却塔制冷在国外叫做FREECOOLING,直译过来就是免费制冷,因取消了冷水机组的运转,节省了能量,从而达到节能的效果。北京地区大型的商场、办公楼、计算机中心等都有内区需要在冬季进行空调制冷,也有不少采用冷却塔进行冬季空调制冷的方式,现将笔者做冷却塔冬季制冷设计的一些经验做一总结。 Chilling by means of cooling tower is called "Free cooling'in English, which means "cooling free ofcharge"in Chinese. Energy efficiency is achieved without operation of chilling unit. Air conditioner cooling is necessary in interior sections of large shopping malls, office buildings and computer centers in winter while cooling tower is also used as another option. This paper gives some experiences of the author in winter chilling design with cooling towers.
作者 李海欣
出处 《工程建设与设计》 2013年第5期196-198,共3页 Construction & Design for Engineering
关键词 开式冷却塔 闭式冷却塔 制冷 内区 防冻 自控 atmospheric coolingtower, closed-circuit cooling tower chilling interior section frost protection automatic control
  • 相关文献

参考文献3

  • 1建设部工程质量安全监督与行业发展司,中国建筑标准设计研究院.《全国民用建筑工程设计技术措施一节能专篇暖通空调·动力(2007版)[M].北京:中国计划出版社,2007.
  • 2住房和城乡建设部工程质量安全监管司,中国建筑标准设计研究院.《全国民用建筑工程设计技术措施》暖通空调·动力(2009版)[M].北京:中国计划出版社,2009.
  • 3GB50189-2005.公共建筑节能设计标准[S].[S].,2005..