摘要 对夹层换热器的传热效率和总传热系数以及带夹层换热器平板型太阳能热水器的热性能进行测试与分析,对比分析三种热水器的平均日效率和平均热损系数。测试结果表明,夹层换热器的换热效率都在85%以上,一天中的平均总传热系数(UA)hx为88.16 W/K;带夹层换热器的平板太阳能热水器的平均日效率为49.8%,低于普通平板太阳能热水器的平均日效率(53.4%),但要高于全玻璃真空管太阳能热水器的平均日效率(48.7%)。 The heat transfer efficiency and overall heat transfer coefficient of mantle heat exchanger have been tested and analyzed. The thermal performance of fiat-plate solar water heater with a mantle heat exchanger have been tested and the mean daily efficiency and mean heat losses coefficient of three kinds of solar water heaters have been analyzed and compared. Experimental results show that the heat transfer efficiency of mantle heat exchanger is about 88.16 W/K. The mean daily efficiency of is above 85 % and overall heat transfer coefficient a flat-plate solar water heater with a mantle heat exchanger can reach up to 49.8% , which is lower than that of a fiat-plate solar water heater without heat exchanger, but higher than that of a all-lass evacuated tubular solar water heater.
作者 黄金保
出处 《应用能源技术》 2013年第5期46-50,共5页 Applied Energy Technology
关键词 夹层换热器 平板太阳能热水器 热性能 平均日效率 Mantle heat exchanger Flat-plate solar water heater Thermal performance Mean dailyefficiency
  • 相关文献

参考文献14

  • 1Mekhilefa S, Saidurb R, Safari A. A review on solar energy use in industries [ J ]. Renewable and Sustain- able Energy Reviews, 2011,15 (4) : 1777 - 1790.
  • 2Xia C, Luo H, Tang R, et al. Solar thermal utiliza- tion in China [ J ]. Renewable Energy, 2004, 29 : 1549 - 1556.
  • 3Solangib K H, Islamb M R, Saidura R, et al. A re- view on global solarenergy policy [ J ]. Renewable and Sustainable Energy Reviews, 2011,15 (4) : 2149 - 2163.
  • 4丁祥,高文峰,刘滔,林文贤.分体承压阳台壁挂式太阳热水器的热性能分析[J].农业工程学报,2011,27(10):233-237. 被引量:5
  • 5宋杰,王作文,孟小平.热-应力耦合场作用下含缺陷压力管道的应力强度因子研究[J].森林工程,2010,26(3):33-36. 被引量:12
  • 6张燕,佟达,宋魁彦.生物质能的热化学转化技术[J].森林工程,2012,28(2):14-17. 被引量:34
  • 7Fraser K F, Hollands G T, Brunger A P. An empiri- cal model for natural convection heat exchangers in SDHW [ J. Solar Energy, 1995 (55) :75 - 84.
  • 8Morrison G L, Nasr A, Behnla M, et al. Analysis of horizontal mantle heat exchangers in solar water heat- ing systems [ J ]. Solar Energy, 1998 (64) : 19 - 31.
  • 9Rosengarten G, Morrison G L, Behnia M. Mixed corl- vection in a narrow rectangular cavity with bottom inlet and outlet [ J ]. International Journal of Heat and Fluid Flow, 2001 (22) : 168 - 179.
  • 10Shah L J. Heat transfer correlations for vertical man- tle heat exchangers [ J ]. Solar Energy, 2000 ( 69 ) : 157 - 171.