期刊文献+

饮水中氟化物比色法分析误差的预测

Variant calculation of fluoride analysis in potable water
暂未订购
导出
摘要 目的 对氟试剂比色法测定饮水中氟化物的分析误差进行预测 ,以保证水质分析数据的可靠性。方法 按水质分析中评价比色法精密度和准确度的 AQC工作程度进行。结果 各种溶液测定的总标准差小于其浓度的 5 %或检出限 ,总平均回收率可信限在允许范围内。结论 用氟试剂比色法测定饮水中氟化物 ,实验室分析误差可控制在容许值内。 Objective In order to pledge data of analysis reliability,that variant analysis of fluoride in potable water was calculated by colorimetric method of fluorine reagent.Methods According to the AQC procedure of analysis water quality evaluated precision and accuracy of colorimetric method.Results Total standard deviation of every solution was less than 5% of the concentration or detection limit.The confident limit of total average rate of recovery in sample kept in range of allowable.Conclusions Colorimetric methods of fluorine reagent to determine fluoride of potable water and the value of variant analysis in the laboratory can be controlled in the range of allowable.
作者 付家华
出处 《中国地方病学杂志》 CAS CSCD 2000年第4期294-295,共2页 Chinese Jouranl of Endemiology
关键词 饮用水 氯化物 误差 比色法 Potable water Fluoride Variant Calcuation
  • 相关文献

参考文献4

  • 1陈守健 鄂学礼 等.水质分析质量控制[M].北京:人民卫生出版社,1987.133.
  • 2张宏陶,生活饮用水标准检验方法注解,1993年,117页
  • 3陈守健,水质分析质量控制,1987年,133页
  • 4中华人民共和国卫生部,生活饮用水标准检验法 ( GB75 0 -85 )[S],1985年,46页