期刊文献+

容积导体对离体蟾蜍心电的影响 被引量:2

The effects of volume conductor on ECG in isolated heart of toad
暂未订购
导出
摘要 目的探讨容积导体对离体蟾蜍心电的影响。方法离体蟾蜍心脏置培养皿中央,培养皿内加入林格氏液,在培养皿周边置电极记录心电。结果心电图R波幅度随心脏周围容积导体的增大明显减小。容积导体由1ml增大到5ml,R波幅度即明显减小,由(0.99±0.12)mV减小到(0.53±0.06)mV,减小46.5%;当容积导体增大到30ml时,R波减小94.9%。结论心电图受心脏周围容积导体或组织液量的影响。 Objective To study the effect of volume conductor on ECG in isolated heart of toad. Methods The isolated toad heart was placed in the middle of petri dish,and ringer's solution was dripped into the petri dish, whose rim was connected with the recording electrodes so as to get ECG.Resuits Amplitude of R wave in ECG decreased distinctively while volume conductor increased. Amplitude of R wave decreased to be 0.53 0.06mv from 0.99 =t= 0.12mv when volume conductor increased from lml to 5ml, and the decreasing rate was 46.5 %. Amplitude less- ened 94.9 % with volume conductor raising to be 30ml. Conclusion ECG could be influenced by volume conductor or volume of tissue fluid around the heart.
出处 《济宁医学院学报》 2013年第2期103-105,共3页 Journal of Jining Medical University
基金 2011年济宁医学院青年科研基金(JYQ2011KM019)
关键词 容积导体 心电图 R波 离体蟾蜍心脏 Volume conductor Electrocardiogram R wave Isolated heart of toad
  • 相关文献

参考文献3

二级参考文献5

  • 1尹炳生 张缗.常规临床心电图学与头胸导联临床心电图学[J].中国循环杂志,1991,6(1):75-8.
  • 2黄宛,临床心电图学(第5版),1998年,551页
  • 3Lu W X,IEEE Trans Biomed Eng,1996年,43卷,2期,211页
  • 4尹炳生,中国循环杂志,1991年,6卷,1期,75页
  • 5邝华俊.医用物理学[M]人民卫生出版社,1989.