期刊文献+

MSCT测量胃癌体积的层厚选取及可重复性 被引量:3

Reproducibility and thickness selection in measurement of gastric cancer volume using MSCTLI
暂未订购
导出
摘要 目的探讨MSCT测量胃癌体积的层厚选取,评价MSCT测量胃癌体积的可重复性。方法将33例胃癌的MSCT图像传输至工作站,分别用3mm、5mm和7mm层厚进行胃癌体积测量,并由另1名医师以5mm层厚对所有胃癌体积进行重复测量。计算观察者内或观察者间的差异。结果 3mm、5mm、7mm层厚测得胃癌体积分别为(65.06±46.87)cm3、(64.74±47.13)cm3和(63.56±45.82)cm3(F=5.409,P<0.05)。3mm和5mm层厚测量胃癌体积差异无统计学意义(P=0.298);3mm和7mm层厚、5mm和7mm层厚测量结果差异有统计学意义(P均<0.05)。3mm和5mm、3mm和7mm、5mm和7mm层厚测量胃癌体积的组内相关系数分别为0.992、0.990、0.988。用3mm、5mm、7mm层厚测量胃癌体积所需时间分别为(30.6±15.5)min、(20.0±11.8)min和(12.3±6.4)min。两名观察者用5mm层厚测量的胃癌体积平均值分别是(64.74±47.13)cm3和(65.32±45.82)cm3,差异无统计学意义(F=1.386,P=0.248),组内相关系数为0.998。结论 MSCT测量胃癌体积时选用3mm和5mm层厚较佳;选用5mm层厚测量胃癌体积节省工作时间;MSCT胃癌体积测量具有较高的一致性和可重复性。 Objective To investigate the slice thickness selection of measuring gastric cancer volume using MSCT, and to evaluate the reproducibility of the measurement of gastric cancer volume with MSCT. Methods MSCT image data of 33 patients with gastric cancer were transferred to the workstation. Gastric cancer volume was measured with the slice thickness of 3 mm, 5 mm and 7 ram, respectively, and was repeatedly measured with 5 mm slice thickness by another experienced radiologist. Intra-observer and inter-observer variability was calculated. Results Gastric cancer volume measured with slice thickness of 3 mm, 5 mm and 7 mm were (65.06±46.87)cm^3 , (64.74±47.13)cm^3 and (63.56±45.82)cm^3 (F=5. 409, P〈0. 05), respectively. Analysis of variance of the repeatedly measured results showed that the differences between 3 mm and 7 mm, 5 mm and 7 mm had statistical significance (all P〈0.05), while the difference between 3 mm and 5 mm had no statistical significance (P: 0. 298). Interclass correlation coefficient of the slice thickness of 3 mm and 5 mm, 3 mm and 7 mm, 5 mm and 7 mm in measuring gastric cancer volume were 0. 992, 0. 990, 0. 988, respectively. Time costed was (30.6±15.5)min, (20. 0±11.8)min and (12.3±6.4)min when measured with slice thickness of 3 mm, 5 mm and 7 mm, respectively. The gastric cancer volumes measured by two observers with 5 mm slice thickness were (64.74±47.13)cm^3 and (65.32±45.82)cm^3 (F=1. 386, P=0. 248), respectively. And the interclass correlation coefficient was 0. 998. Conclusion It is better to select slice thickness of 3 mm and 5 mm to measure gastric cancer volume using MSCT. Selection of 5 mm slice thickness measuring gastric cancer volume can spare time. Measurement of gastric cancer volume with MSCT is of high consistency and reproducibility and has clinical value.
出处 《中国医学影像技术》 CSCD 北大核心 2013年第5期757-760,共4页 Chinese Journal of Medical Imaging Technology
基金 辽宁省自然科学基金(20092121)
关键词 体层摄影术 X线计算机 胃肿瘤 体积 重复性 Tomography, X-ray computed Gastric neoplasms Volumetry Reproducibility
  • 相关文献

参考文献8

二级参考文献63

共引文献58

同被引文献22

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部