摘要 在自然通风条件下,通过火车站候车室内外环境参数的测试以及旅客热感觉问卷调查相结合的方式,对甘肃地区火车站候车室夏季室内热舒适状况进行了现场调查。调查结果表明,甘肃地区火车站候车室实测夏季的热中性温度为26.4℃,80%旅客可接受的温度范围为24.2~28.5℃。结果为甘肃地区火车站建筑候车室内热环境设计提供了依据。 In the natural ventilation conditions, through the and outside environment parameters test and passengers thermal way of the combination of the railway station waiting room inside sense value questionnaire survey, railway station waiting room in Gansu indoor thermal comfort investigation was carried out. The results indicated that in summer the neutral temperature is 26.1℃, the temperature of the 80% comfort zone is 24.0-28.3℃. This article results provide the basis for Gansu railway station waiting room internal environment design.
出处 《制冷与空调(四川)》 2013年第2期166-170,共5页 Refrigeration and Air Conditioning
关键词 火车站 自然通风 热舒适 热感觉 Railway station Natural ventilation Thermal comfort Thermal sense