摘要
超临界直流锅炉给水流量调整不当已成为机组停机的重要原因,详细介绍了直流锅炉湿态、干态及干湿态转换时给水流量的调整方法以及各阶段的相关注意事项,以供相关人员参考。
The improper adjustment of feed water flow for supercritical once-through boiler became the important reason to lead unit outage.The feed water flow adjustment methods for oncethrough boiler under the wet state,the dry state and the transforming process of wet state to dry state were introduced in detail,and the matters needing attention in each period were presented,which can be used as reference for related personnel.
出处
《华电技术》
CAS
2013年第4期33-36,39,共5页
HUADIAN TECHNOLOGY
关键词
超临界
直流锅炉
给水流量
调节
supercritical
once-through boiler
feed water flow
adjustment
dry state
wet state
transforming of wet state to dry state