Ruby fluorescence pressure scale: Revisited 被引量:1

Ruby fluorescence pressure scale: Revisited
原文传递
导出
摘要 Effect of non-hydrostatic stress on X-ray diffraction in a diamond anvil cell (DAC) is studied. The pressure gradient in the sample chamber leads to the broadening of the diffraction peaks, which increase with the hkl index of the crystal. It is found that the difference between the determined d-spacing compressive ratio d/do and the real d-spacing compressive ratio dr/do is determined by the yield stress of the pressure transmitting media (if used) and the shear modulus of the sample. On the basis of the corrected experiment data of Mao et al. (MXB86), which was used to calibrate the most widely used ruby fluorescence scale, a new relationship of ruby fluorescence pressure scale is corrected, i.e., P = (1904/9.827)[(1 + △λ/λ0)9.827 - 1]. Effect of non-hydrostatic stress on X-ray diffraction in a diamond anvil cell (DAC) is studied. The pressure gradient in the sample chamber leads to the broadening of the diffraction peaks, which increase with the hkl index of the crystal. It is found that the difference between the determined d-spacing compressive ratio d/do and the real d-spacing compressive ratio dr/do is determined by the yield stress of the pressure transmitting media (if used) and the shear modulus of the sample. On the basis of the corrected experiment data of Mao et al. (MXB86), which was used to calibrate the most widely used ruby fluorescence scale, a new relationship of ruby fluorescence pressure scale is corrected, i.e., P = (1904/9.827)[(1 + △λ/λ0)9.827 - 1].
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期402-406,共5页 中国物理B(英文版)
基金 Project supported by the Defense Industrial Technology Development Program of China (Grant No. B1520110001) the National Natural Science Foundation of China (Grant No. 10874158) the Project of China Academy of Engineering Physics (Grant Nos. 2010A0101001 and 2008A0101001)
关键词 non-hydrostatic stress ruby fluorescence pressure scale diamond anvil cell non-hydrostatic stress, ruby fluorescence pressure scale, diamond anvil cell
  • 相关文献

参考文献32

  • 1Forman R A, Piermarini G J, Barnett J D and Block S 1972 Science 176 284.
  • 2Mao H K, Bell P M, Shaner J W and Steinberg D J 1978 J. Appl. Phys. 49 3276.
  • 3Mao H K, Xu J and Bell P M 1986 J. Geophys. Res. 91 4673.
  • 4Aleksandrov I V, Goncharov A E Zisman A N and Stishov S M 1987 Soy. Phys. JETP 66 384.
  • 5Zha C S, Mao H K and Hemley R J 2000 Proc. Natl. Acad. Sci. USA 97 13494.
  • 6Holzaphel W B 2003 J. Appl. Phys. 93 1813.
  • 7Dorogokupets P I and Oganov A R 2003 Dokl. Earth Sci. 391A 854.
  • 8Dewaele A, Loubeyre P and Mezouar M 2004 Phys. Rev. B 70 094112.
  • 9Chijioke A D, Nellis W J, Soldatov A and Silvera I F 2005 J. AppL Phys. 98 114905.
  • 10Silvera I E Chijioke A D, Nellis W J, Soldatov A and Tempere J 2007 Phys. Stat. Sol. (b) 244 460.