期刊文献+

核动力装置自然循环一回路冷却剂流量测量技术 被引量:1

Research on nuclear power plant natural circulation coolant flow rate measurement
在线阅读 下载PDF
导出
摘要 针对压水堆核动力装置自然循环工况下一回路冷却剂流量测量的难题,提出一种基于16Nγ噪声和相关分析的测量方法。完成测量系统的设计,研制16Nγ探测器、放大电路和信号处理装置样机。采用一种自适应脉冲响应函数与滑动平均滤波相结合的算法,解决常规互相关算法峰值不明显和容易出现干扰峰的问题,并对测量系统的误差进行分析。最后利用样机在某压水堆核动力装置上进行试验,给出了试验结果。 In order to measure the PWR coolant flow rate in natural circulation condition,a contact free flow rate measurement by correlation analysis of ^16Nγ fluctuations is put forward in this paper. The principle is explained, the design of the measurement system is presented. In practice, cross-correlation calculation tends to produce flat peak plateau or multiple peaks, leading to a significant error in peak detection. To overcome this problem, an auto-adaptive impulse response function (AAIRF)estimation technique is thus introduced in this paper. In addition, we show that more accurate results can be obtained if a moving-average-filter-based cross-correlation function is combined with AAIRF. The error of the measuring system is discussed and the result of the carried experiments is presented at last.
出处 《舰船科学技术》 北大核心 2013年第4期65-69,共5页 Ship Science and Technology
基金 基金项目:J082010B002
关键词 自然循环 PWR冷却剂流量 ^16Nγ噪声 相关分析 传递函数 natural circulation PWR primary flow rate ^16Nγfluctuations correlation analysis transfer functions
  • 相关文献

参考文献9

二级参考文献18

共引文献25

同被引文献56

  • 1卢川,张勇,鲁剑超,董化平.基于CFD方法的自然循环反应堆冷却剂流动特性分析[J].核动力工程,2012,33(S1):111-114. 被引量:5
  • 2黄代顺,蒋孝蔚,余红星.非能动安全壳冷却系统CFD冷凝和蒸发模型研究[J].核动力工程,2013,34(S1):188-191. 被引量:7
  • 3彭斯亮,侯玉林.自然循环余热锅炉的安装[J].能源与节能,2014,0(2):143-144. 被引量:2
  • 4阎昌琪,曹夏听.核反应堆安全传热[M].哈尔滨:哈尔滨工程大学出版社,2010.
  • 5秦立新.新一代"水下幽灵"若隐若现[N].解放军报,2013-05-02.
  • 6Sun L, Sun L C, Yan C Q, et al. Conceptual Design and Analysis of a Passive Residual Heat Removal System for a 10MW Molten Salt Reactor Experiment [ J ]. Progress in Nuclear Energy ,2014,70 ( 11 ) : 149 -158.
  • 7Min B Y, Park H S, Shin Y C, et al. Experimental Verification on the Integrity and Performance of the Passive Residual Heat Removal System for a SMART Design with VISTA-ITL[ J ]. Annals of Nuclear Ener- gy,2014,71 (9) :118 - 124.
  • 8Nitin M, Jyeshtharaj B J, Arun K N, et al. Numerical Investigation of Three-dimensional Natural Circulation Phenomenon in Passive Safety Systems for Decay Heat Removal in Large Pools [ J ]. International Journal of Heat and Mass Transfer,2015,81 ( 2 ) :659 - 680.
  • 9Yu Y, Niu F L, Wang S F, et al. One-dimensional Model for Containment in APIO00 Nuclear Power Plant Based on Thermal Stratification [ J ]. Applied Thermal Engineering,2014,70 ( 9 ) :25- 32.
  • 10Cheng X,Erbaeher F J, Neitzel H J. Passive Contain- ment Cooling by Natural Air Convection and Thermal Radiation after Severe Accidents [ J]. Nuclear Engi- neering and Design,2000,202(12) : 219-229.