期刊文献+

一侧上颌骨缺损赝复体修复前后咬合力分布的变化 被引量:3

Occlusal force distribution of unilateral maxillary defect patients with obturators
原文传递
导出
摘要 目的探讨一侧上颌骨缺损患者赝复体修复后的咬合力分布状况。方法以2007~2009年因一侧上颌骨缺损制作支架中空式永久性赝复体修复的患者为研究对象。采用T-scanⅡ咬合分析仪测定患者咬合加载时间(MLT)及咬合力分布状况。结果赝复体戴入前后咬合加载时间差异无统计学意义(P>0.05)。赝复体戴入后咬合力中心(COF)向缺损侧偏移约3.9mm,缺损区可承受约12.67%的咬合力,同戴入前相比差异均有显著统计学意义(P<0.01)。结论赝复体修复一侧上颌骨缺损一定程度上改善了患者的咬合力分布。 Objective To observe the distribution of occlusal force of patients with obturators. Methods Fifteen unilateral maxillary defect patients with obturators were recruited for this study. The distribution of occlusal force was observed with T-Scan 11 Computerized Occlusal Analysis system. Results The difference of MLT was not significant for patients with and without obturators (P〉0.05). With obturators, the COF moved to defective side about 3.9mm and the defective side could bear 12.67% occlusal force (P〈0.01). Conclusion The occlusal force distribution of unilateral maxillary defect Patients was improved by wearin obturators .
出处 《现代口腔医学杂志》 CAS CSCD 2013年第2期91-94,共4页 Journal of Modern Stomatology
基金 首都医学发展科研基金重点课题(2009-2083)
关键词 上颌骨缺损 赝复体 咬合力 Maxillary defects Obturator Occlusal force distribution
  • 相关文献

参考文献10

  • 1赵铱民,高元,安燕,王筠,黄城外,艾勇.上颌骨缺损的分类及修复疗效[J].实用口腔医学杂志,1996,12(1):31-34. 被引量:39
  • 2Sun J, Jiao T, Tie Y, et al. Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect. Journal of Oral Rehabilitation, 2008, 35(9): 695-699.
  • 3Matsuyama M, Tsukiyama Y, Tomioka M, et al. Clinical assessment of chewing function of obturator prostheses wearers by objective measurement of masticatory performance and maximum occlusal force. Int J Prosthodont, 2006, 19 (3): 253-257.
  • 4Aramany MA. Basic principles of obturator design for partially edentulous patients. Part I. Classification. J Prosthet Dent, 1978, 40(5): 554.
  • 5Gonzalez Sequeros O, Garrido Garcia VC, Garcia Cartagena A. Study of ocelusal contact variability within individuals in a position of maximum intercuspation using the T-Scan system. J Oral Rehabil, 1997, 24(4): 287-290.
  • 6Garrido Garcia VC, Garcia Cartagena A, Gonzalez Sequeros O. Evaluation of occlusal contacts in maximum intercuspation using the T-Scan system. J Oral Rehabil, 1997, 24(12): 899-903.
  • 7Kirveskari P. Assessment of occlusal stability by measuring contact time and centric slide. J Oral Rehabil, 1999, 26 (10): 763-766.
  • 8Kenji O, Shigezo H, Iwao H. A clinical application of the T-Scan II system usefulness for evaluating occluasal contacts of complete denture wears. Kokubyo Gakkai Zasshi, 2002, 69 (4): 277-284.
  • 9Mizui M, Nabeshima F, Tosa J, et al. Quantitative analysis of occlusal balance in intercuspal position using the T-Scan system. Int J Prosthodont, 1994, 7(1): 62-71.
  • 10赵铱民,刘宝林,袁井圻,黄辉.上颌骨切除术与赝复体修复[J].实用口腔医学杂志,1998,14(1):41-43. 被引量:25

二级参考文献3

共引文献61

同被引文献19

引证文献3

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;