期刊文献+

环介导等温扩增技术检测克氏螯虾样品中的副溶血性弧菌 被引量:3

Application of LAMP to Detect Vibrio parahaemolyticus in Cambarus clarkii
在线阅读 下载PDF
导出
摘要 建立了环介导等温扩增技术检测副溶血性弧菌的方法。以副溶血性弧菌tlh基因作为靶基因,设计特异性引物,建立了环介导等温扩增(LAMP)检测方法,并分别采用LAMP检测方法和国家标准方法(GB/T4789.7-2008)对克氏螯虾样品中的副溶血性弧菌进行检测。结果表明,建立的LAMP方法最低检出限为1×101 cfu/mL;对6种细菌共8株菌进行LAMP法扩增,仅3株副溶血性弧菌得到阳性扩增。建立的LAMP检测方法与国家标准检测方法检测结果一致,准确度高。 In this paper,a loop-mediated isothermal amplification (LAMP) method was developed to detect Vibrio parahaemolyticus in crayfish samples,compared to the national standard method (GB/T4789.7-2008). The results showed that LAMP was convenient,high sensitive, specific, and suitable for the site fast detection of Vibrio parahaemolyticus. The detection limit of LAMP was 1 × 101 cfu/mL. Detection of artificially polluted Cambarus clarkii samples by LAMP showed the consistent results with those performed by national standard method.
作者 张毅 胡定金
出处 《河南农业科学》 CSCD 北大核心 2013年第3期128-130,共3页 Journal of Henan Agricultural Sciences
基金 湖北省农业科技创新中心农业环境与农产品安全研究分中心项目(2011-620-000-001-3)
关键词 环介导等温扩增技术 溶血性弧菌 克氏螯虾 loop-mediated isothermal amplification Vibrio parahaemolyticus Cambarus clarkii
  • 相关文献

参考文献12

二级参考文献93

共引文献93

同被引文献79

  • 1刘伟,蔡国瑞,刘国红,张霞.等温扩增技术在检测食品中金黄色葡萄球菌的应用[J].食品研究与开发,2013,34(24):225-228. 被引量:3
  • 2Blackstone G M,Nordstrom J L, Bowen M D, et al. Use of a real time PCR assay for detection of the ctxA gene of Vibrio cholerae in an environmental survey of Mobile Bay[J]. J Microbiol Meth, 2007,68 (2) : 254- 259.
  • 3Notomi T, Okayam A H, Masubuchi H, et al. Loop- mediatedisothermal amplification of DNA[J]. Nucleic Acids Res,2000,28(12) :e63.
  • 4Chen S Y,Ge B L. Development of a toxR-based loop- mediated isothermal amplification assay for detecting Vibrio parahaemolyticus [J]. BMC Microbiol, 2010, 10:41-49.
  • 5Wang F,Jiang L, Ge B L. Loop-mediated isothermal amplification assays for detecting shiga toxin-producing Escherichia coli in ground beef and human stools[J]. J Clin Microbiol, 2012,50 ( 1 ) : 91-97.
  • 6Xu Z B, Li L,Chu J,et al. Development and application of loop-mediated isothermal amplification assays on rapid detection of various types of staphylococci strains [J]. Food Res Int,2012,47(2) 166-173.
  • 7Yeh H Y, Shoemaker C A,Klesius P H, et al. Evalu- ation of a loop-mediated isothermal amplification method for rapid detection of channel catfish Ictalu- rus punctatus important bacterial pathogen Edwardsiella ictaluri [J]. J Mierobiol Methods, 2005,63 ( 1 ) : 36-44.
  • 8Gao H, Lei Z,Jia J, et al. Application of loop-mediated isothermal amplification for detection of Yersinia en- terocolitica in pork meat[J]. J Microbiol Methods, 2009,77 (2) : 198-201.
  • 9Notomi T, Okayama H, Masubuchi H, et al. Loop-mediated isother- mal amplification of DNA[J]. Nucleic Acids Res, 2000, 28(12):E63.
  • 10Hang Minh Pham, Chic Nakajima, Kazuhiko Ohashi, et al. Loop- Mediated Isothermal Amplification for Rapid Detection of Newcastle Disease Virus[J]. Journal of clinical microbiology, 2005, 43(4): 1646- 1650.

引证文献3