期刊文献+

256层螺旋CT肺动脉成像对比剂应用的优化方案研究 被引量:24

Optimized delivery protocol of contrast medium in computed tomography pulmonary angiography with 256-slice spiral CT
暂未订购
导出
摘要 目的研究不同对比剂用量和注射流速情况下CT肺动脉成像(CTPA)的影像质量,探讨256层螺旋CT肺动脉成像中对比剂应用的优化方案。方法 60例临床上怀疑肺动脉栓塞的患者随机分为两组A组和B组,对比剂用量和注射流速分别为:A组35ml对比剂+30ml生理盐水,注射流速5ml/s;B组25ml对比剂+30ml生理盐水,注射流速4.5ml/s。比较分析两组的肺动脉节段、上腔静脉、升主动脉的CT值以及肺动脉节段的影像质量。结果两组各肺动脉节段CT值差异无明显统计学意义(P>0.05),上腔静脉和升主动脉CT值差异有统计学意义(P<0.05);两组肺动脉影像质量均可满足诊断要求。结论应用256层螺旋CT进行肺动脉成像时,较低的对比剂用量和相对较低的注射流速条件下,肺动脉显示良好,降低对比剂肾病的发生率,可以满足临床诊断的需要。 Objective To compare the image quality of computed tomography pulmonary angiography (CTPA) required with contrast medium (CM) of different volume and inject-rate using a 256-slice CT scanner and to investigate the optimized delivery protocol of contrast medium in computed tomography pulmonary angiography. Methods 60 patients suspected pulmonary embolism undergoing computed tomography pulmonary angiography were randomly divided into two groups, each containing 30 patients. The volume of contrast medium was 35 ml with the inject-rate 5 ml/s in group A, meanwhile that of group B was 25 ml with the inject-rate 4.5 ml/s. All followed by a saline flush of 30 mL The CT values of pulmonary arteries, superior vena cava (SVC) and ascending aorta (AA) were compared respectively. Image quality of pulmonary arteries was evaluated. Results There was no statistical significance in the CT values of pulmonary arteries ( P 〉0.05), and there was statistical significance in the CT values of superior vena cava (SVC) and ascending aorta (AA) in two groups ( P d0.05), two groups of pulmonary artery image quality could be diagnostic. Conclusion The use of proper injection-related factors in CTPA, such as a decreased CM volume and a relatively low flow rate can enable pulmonary artery contrast enhancement with a 256-slice CT scanner.
出处 《医学影像学杂志》 2013年第3期393-396,共4页 Journal of Medical Imaging
关键词 体层摄影术 X线计算机 肺动脉 对比剂 Tomography, X-ray computed Pulmonary artery Contrast media
  • 相关文献

参考文献12

二级参考文献51

  • 1章作铨,张皓,高洁冰,秦培鑫,韩铭钧,刘小彬,何燕丽,钟国梅.MSCT肺动脉成像中对比剂优化剂量的初步研究[J].广东医学,2006,27(5):632-634. 被引量:11
  • 2李真林,杨志刚,郭应坤,余建群,李媛,陈宪,谈伟.管电流调制技术在多层螺旋CT胸部检查中的应用评价[J].中国医学影像技术,2006,22(6):858-860. 被引量:7
  • 3刘建新,孙红霞,唐光健,蒋学祥.多层螺旋CT低剂量对比剂肺动脉成像[J].中国医学影像技术,2006,22(7):1012-1014. 被引量:23
  • 4Prolngo JD,Gilkeson RC,Diaz M,et al.CT pulmonary angiongraphy:a comparative analysis of the utilization patterns in emergency department and hospitalized patients between 1998 and 2003.AIR,2004,183(4):1093-1096.
  • 5Diederich S.Radiation dose in helical CT for detection of pulmonary embolism.Eur Radiol,2003,13(7):1491-1493.
  • 6Tack D,De Maertelaer V,Petit W,et al.Multl-detector row CT pulmonary angiography:comparison of standard-dose and simulated low-dose techniques.Radiology,2005,236(1):318-325.
  • 7Coche E,Vvnckier S,Octave-Priqnot M.Pulmonary embolism:radiation dose with multi-detector row CT and digital angiography for diagnosis.Radiology,2006,240(3):690-697.
  • 8Mayo JR.Radiation dose issues in longitudinal studies involving computed tomngraphy.Proc Am Thorac,2008,5(9):934-939.
  • 9Kalra MK,Rizzo SM,Novelline RA.Reducing radiation dose in emergency computed tomography with automatic exposure control techniques.Emerg Radiol,2005,11(5):267-274.
  • 10Lee CH,Coo JM,Ye HJ,et al.Radiation dose modulation techniques in the multidetector CT era:from basics to practice.Radiographic,2008,28(5):1451-1459.