摘要 以福建省消防总队灭火救援攻坚组集训工作为平台,抽取两个有代表性的攻坚组,在模拟灭火救援实战环境中进行各项指标测试。测试人员佩戴6.8L呼吸器进行三种方式的测试。根据所得数据,呼吸器理论使用时间与实际使用时间相差较大。建议呼吸器报警器采用智能化设置,增加震动提示等;气瓶储存压力以28~30MPa为宜;增加9L呼吸器的配置;为官兵建立呼吸器使用情况卡。 Based on the training of crucial groups on fire fighting and rescue in Fujian general fire brigade, the indexes of air res- pirator were tested under the simulated fire fighting and rescue circumstance by 2 typical crucial groups. The 6.8 L air respira- tor was tested by test people in 3 ways. The difference between theoretical service time and actual service time is big based on the test data. It was suggested that the alarm system of air res- pirator should be intelligentized and should be added with prompt shake; the pressure of air bottle should be 28 - 30 MPa; there should be more 9 L air respirator; there should be card of using situation of air respirator for every officer and soldier.
机构地区 莆田市消防支队
出处 《消防科学与技术》 CAS 北大核心 2013年第3期300-302,共3页 Fire Science and Technology
关键词 空气呼吸器 使用时间 负重登楼 air respirator service time loaded climbing stairs