期刊文献+

两种方法测定水样中总氰化物含量的比较 被引量:4

Comparison of Two Methods for Assaying of Total Cyanide in Water Samples
在线阅读 下载PDF
导出
摘要 分别采用连续流动注射法和传统分光光度法测定水样中总氰化物的含量。对检测结果进行统计学中的F和t检验,结果表明这两种方法测得的结果数据无显著性差异,精密度、准确度等指标均符合分析标准要求。连续流动注射法的自动化程度更高,操作更简便、灵敏度更高。 Total cyanide in water samples was respectively assayed with flow injection analysis and spectrophotometry. The F - test and t - test showed that the content data acquired from these two methods had no significant differences to determine the content of total cyanide in water samples, and the precision and accuracy were accorded with the analysis criteria. The flow injection analysis was easier operation, and had higher degree of automation and higher sensitivity than speetrophotometry.
出处 《广州化工》 CAS 2013年第6期133-135,共3页 GuangZhou Chemical Industry
关键词 水样 总氰化物 连续流动注射法 分光光度法 water samples total cyanide flow injection analysis spectrophotometry
  • 相关文献

参考文献6

  • 1国家环境保护总局.水和废水监测分析方法[M].北京:中国环境科学出版社,2002,12.144-153.
  • 2环境保护部.HJ484-2009水质氰化物的测定容量法和分光光度法[S].北京:中国环境出版社,2009.
  • 3Maria Teresa Fernandez - Argtielles ,Jose M. Costa - Fernandez, Rosario Pereiro, et al. Room temperature phosphorimetric determination of cya- nide based on triplet state energy transfer[ J]. Analytica Chimica Acta, 2003,491:27 - 35.
  • 4李文奇,白芸.荧光光度法测定食用酒精中氰化物含量的研究[J].理化检验(化学分册),2000,36(2):49-50. 被引量:14
  • 5Terri T. Christison, Jeffrey S. Rohrer. Direct determination of free cya- nide in drinking water by ion chromatography with pulsed amperometric detection[ J]. Journal of Chromatography A,2007, 1155:31 - 39.
  • 6潘腊青.银离子电极法现场快速测定水中氰化物[J].中国环境监测,2000,16(3):51-53. 被引量:23