监测呼出和部分重吸入气体中CO_2测心排血量
被引量:2
摘要
以转化后的Fick公式为依据,通过监测呼出、部分重吸入气体中的CO_2测定心排血量是一种无创、近连续、精确度高的测量心排血量方法。本文对其作用原理、测量效果、优点及局限性作一综述。
出处
《国外医学(麻醉学与复苏分册)》
2000年第4期206-207,共2页
Foreign Medical Sciences(Anesthesilolgy and Resuscitation)
参考文献9
-
1Watt RC et al. Anesthesiology . 1998
-
2Jopling MW et al. Anesthesiology . 1998
-
3Guzzi L. et al. Anesthesiology . 1998
-
4Haryadi DG et al. Anesthesiology . 1998
-
5Kück K et al. Anesthesiology . 1999
-
6Kück K et al.SCCM,1999;abstract No[].D.
-
7Orr J et al. Critical Care Medicine . 1999
-
8Johnson KB et al. Anesthesiology . 1998
-
9Haryadi DG et al. Anesthesiology . 1998
同被引文献21
-
1Osterlund B,Gedeon A,Krill P,et al. A new method of using gas exchange measurement for the noninvasive determination of cardiac output, clinical experiences in adults following cardiac surgery. Acta Anaesthesiol Scand,1995,39:727.
-
2Bailey PL, Haryadi DG, Orr JA, et al. Partial CO2 rebreathing Fick technique for noninvasive measurement of cardiac output. Anesthesia Analgesia, 1998,86:124.
-
3Watt RC, Loeb RG,Orr J. Comparison of a new non-invasive cardiac output xeehnique with invasive bolus and continuous thermodilution. Anesthesiology, 1998,89 : 536.
-
4Maxwell RA,Gibson JB,Slade JB,et al. Noninvasive cardiac output by partial CO2 rebreathing after severe chest traum. Traum,2001,51.849.
-
5Odenstedt H, Stenqvist O, Lundin S. Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients, Acta Anaesthesiol Scand,2002,46 : 152.
-
6Johnson KB, Haryadi DG,JA Orr,et al. Influence of pulmonary edema on noninvasive measurement of cardiac output using partial CO2 rehreathing in a canine model.Anesthesiology, 1998,89 : 535.
-
7Kobayashi Y ,Andoh Y , Fujinami T ,et d. hnpedance cardiography for estimating cardiac output during submaximal and maximal work[J]. Appl Phy siol, 1978,45 ( 3 ) .- 459-462.
-
8Keyl C,|lodig G,Lemberger P,et a/. A comparision of the use of transoesophageal dopper and thermodilution techniques for cardiac output detemination[J]. Eur Anaesthesiol, 1996,13 (2) : 136-142.
-
9Valtier B, holley B P, BeIot J P, et al. Noninvasive monitoring of car- diac output in critically ill patients using transesophageal Doppler[J]. Respir Crit Care Med, 1998,158( l ) :77-83.
-
10Abrams J H ,Weber R E ,Holmen K D. Continuous cardiac output de- termination using transtracheal Doppler:initial results in humans[J]. Anesthesiology, 1989,71 ( 1 ) : 1 1-15.
二级引证文献7
-
1董国良,胡德,王玉嘉,胡智勇,钱刚,朱年.复合麻醉中应用多巴胺维持血流动力学稳定的临床研究[J].上海医学,2005,28(8):707-709.
-
2刘琼,黄纪坚,漆洪波,徐昉.潮气量设置对部分二氧化碳重复吸入心输出量测定准确性影响的动物实验研究[J].激光杂志,2009,30(1):90-91. 被引量:2
-
3周玲,汤蓓,相鹏,陈俭.脉搏指数连续心输出量技术在重型颅脑损伤液体管理中的应用分析[J].中华全科医学,2015,13(2):216-218. 被引量:5
-
4李丹,张玲萍,张莲玉,雷小平,董文斌.早产儿应用肺泡表面活性物质前后血流动力学的监测及护理研究[J].西南医科大学学报,2018,41(3):263-267. 被引量:2
-
5郑艳萍.颈动脉超声检测与经胸超声心动图测量心输出量的比较[J].心血管康复医学杂志,2018,27(4):462-465. 被引量:1
-
6周筱燕,高娜.TIPSS对门静脉高压患者左心室和肺血管的影响[J].中国现代医学杂志,2018,28(14):94-98. 被引量:1
-
7宋艳,裴雪梅,江蓓.电子心力测量法无创检测新生儿血流动力学指标参考范围的探讨[J].数理医药学杂志,2019,32(10):1428-1430. 被引量:1
-
1张传生.让肺自由地呼吸[J].大众健康,2006(1):10-13.
-
2王保国.测量心输出量的新方法:部分二氧化碳重吸入法[J].引进国外医药技术与设备,2000,6(2):57-60.
-
3刘英玲,李志钢,刘红玲,梁建玲,刘珍兰,梁栋蓉,高黎黎,苍艳,冀建英.人工气道管理的护理进展[J].中华护理杂志,2002,37(7):534-536. 被引量:242
-
4沈永辉,周健,章小君,李秋月.自动角度测量仪用于测量全髋关节置换术中前倾角的效果[J].临床骨科杂志,2015,18(4):429-432. 被引量:3
-
5龚倩,葛建军,葛圣林,林敏,周汝元.无创正压通气在体外循环术后急性呼吸衰竭患者中的应用[J].中国循环杂志,2012,27(3):212-215. 被引量:20
-
6茅磊,王汉东.脊髓损伤实验模型的制备及评价[J].中国微侵袭神经外科杂志,2009,14(12):574-576.
-
7陈锐,万蓬,侯建国.移植物在尿道狭窄手术中的应用[J].国外医学(泌尿系统分册),2004,24(3):289-293.
-
8薛小飞,张若冰,刘伟,裴磊,赵忠奇,杜立学.两孔法免钛夹与传统腹腔镜胆囊切除术的对比研究[J].腹腔镜外科杂志,2011,16(11):852-854. 被引量:3
-
9王爱峰,盛瑰丽,崔玉芹.论人工气道的湿化[J].中华腹部疾病杂志,2006,6(3):220-221.
-
10王令平,刘仲凯,许波,王朝晖,李希明,杜晨,王飞,陈作雷.经氧合器吸入气体麻醉剂对机体氧耗和心肺复苏的影响[J].临沂医学专科学校学报,2004,26(1):19-21.